text.skipToContent text.skipToNavigation
Series CFB

Series CFB

The pilot of these indirectly operated solenoid valves controls the diaphragm position through a differential pressure. These valves are therefore particularly suitable for controlling high fluid flow rates and require very low working pressures to operate.
Ports: from G3/8 to G2.
The standard diaphragm is supplied in NBR.
On demand it can be supplied in FKM or EPDM.
Series
there are no salable codes online
If you have entered Filters, try changing them or look in the "Configurator" tab
Full screen
Your configuration
Coding example
CFB - A 1 3 L - R 1 - B7 E
CFB SERIES
A OPERATION
A = indirect
B = direct with linked diaphragm
D = direct
E = indirect with coil for heavy-duty applications
1 NUMBER OF WAYS - POSITIONS
1 = 2/2-way - NO
2 = 2/2-way - NC
3 = 3/2-way - NC
3 CONNECTIONS
1 = G1/8
2 = G1/4
3 = G3/8
4 = G1/2
5 = G3/4
6 = G1
7 = G1 1/4
8 = G1 1/2
9 = G2
L ORIFICE DIAMETER
A = 1.4 mm
B = 2 mm
C = 2.5 mm
D = 2.8 mm
F = 4 mm
G = 6 mm
J = 8 mm
L = 11.5 mm
M = 13 mm
N = 13.5 mm
P = 18 mm
R = 26 mm
T = 32 mm
X = 45 mm
Z = 50 mm
R SEALS MATERIAL
R = NBR
W = FKM
E = EPDM (on demand)
1 BODY MATERIAL
1 = brass
2 = alimentary anti-limestone nickel-plated brass for high temperatures (on demand)
3 = alimentary nickel-plated brass (on demand)
B7 SOLENOID DIMENSION
B7 = 22 mm
B8 = 30 mm
B9 = 36 mm
E SOLENOID VOLTAGE
B = 24 V AC 50 Hz
D = 110 V AC 50/60 Hz
E = 230 V AC 50/60 Hz
2 = 12 V DC
3 = 24 V DC

Series CFB - indirectly operated - 2/2 NO

TABLE NOTE:
* = choose the suitable solenoid according to the TABLE FOR THE COUPLING BETWEEN SOLENOID AND VALVES

EV46



Mod. Function Ports Ø Orifice (mm) Kv (m³/h) Pressure min÷max (bar) A B C F G H L SW SW1
CFB-E13L-R1-* 2/2 NO G3/8 11.5 2.6 0.1 ÷ 15 [ AC / DC ] 12 32.5 78.5 41.9 57 M8x0.75 22 24 13.5
CFB-E14N-R1-* 2/2 NO G1/2 13.5 3.5 0.1 ÷ 15 [ AC / DC ] 15 39.7 85.7 45 69 M8x0.75 22 30 13.5
CFB-A15P-R1-* 2/2 NO G3/4 18 5.8 0.2 ÷ 15 [ AC / DC ] 18 46.5 92.7 54.4 74 M8x0.75 22 36 13.5
CFB-A16R-R1-* 2/2 NO G1 26 9.5 0.2 ÷ 12 [ AC / DC ] 22.5 59.8 104.5 71 93 M8x0.75 22 45 13.5
CFB-A17T-R1-* 2/2 NO G1 1/4 32 12.5 0.4 ÷ 12 [ AC / DC ] 27.5 73.5 130 86.6 111 G1/8 30 55 14
CFB-A18X-R1-* 2/2 NO G1 1/2 45 31 0.4 ÷ 10 [ AC / DC ] 31 85 138.3 110 138 G1/8 36 62 14
CFB-A19Z-R1-* 2/2 NO G2 50 45 0.4 ÷ 10 [ AC / DC ] 37.5 98.8 152 110 145 G1/8 36 75 14


We think you are in United States.