text.skipToContent text.skipToNavigation
Mod. CSV

Mod. CSV

Series
Accessories
3 Products found
Mod. CSV
Mod. CSV
Mod. CSV
Full screen
Your configuration
SERIES CST, CSV, CSH CODING EXAMPLE
CS T 2 2 0 N 5 EX
CS SERIES
T TYPE OF SLOT:
T = T-slot
V = V-slot
H = H-slot
2 OPERATION:
2 = Reed NO
3 = Magnetoresistive
4 = Reed NC
5 = Hall effect
2 CONNECTIONS:
2 = 2 wires (Reed only)
3 = 3 wires
5 = 2 wires with M8 connector (Reed only)
6 = 3 wires with M8 connector
0 POWER SUPPLY VOLTAGE:
0 = 10 ÷ 110 V DC; 10 ÷ 230 V AC (PNP)
1 = 30 ÷ 110 V DC; 30 ÷ 230 V AC (PNP)
2 = 3 wires cst (PNP)
3 = 10 ÷ 30 V AC/DC (PNP)
4 = 10 ÷ 27 V DC (PNP)
N NOTE (CST/CSV-250N only):
N = according to norm
5 LENGTH OF THE CABLE:
= 2m (CST and CSV only)
2 = 2m (CSH only)
5 = 5m
EX
SERIES CSB, CSC, CSD CODING EXAMPLE
SERIES CSG CODING EXAMPLE

Magnetic proximity switches with M8 3-pin connector for V-slot

Cable length: 0.3 m



Mod. Operation Connection Voltage Output Max. current Max Load Protection
CSV-250N Reed 2 wires M8 male 3 pin 10 ÷ 110 V AC/DC - 250 mA 10 VA / 8 W None
CSV-262 Reed 3 wires M8 male 3 pin 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing
CSV-362 Magnetoresistive 3 wires M8 male 3 pin 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage
Note for 2-wire switch Mod. CSV-250N:
in case of polarity reversing the sensor will still be operating, but the LED diode won't turn on.

Magnetic proximity switches with M8 3-pin connector for V-slot

Cable length: 0.3 m



Mod. Operation Connection Voltage Output Max. current Max Load Protection
CSV-250N Reed 2 wires M8 male 3 pin 10 ÷ 110 V AC/DC - 250 mA 10 VA / 8 W None
CSV-262 Reed 3 wires M8 male 3 pin 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing
CSV-362 Magnetoresistive 3 wires M8 male 3 pin 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage
Note for 2-wire switch Mod. CSV-250N:
in case of polarity reversing the sensor will still be operating, but the LED diode won't turn on.

Magnetic proximity switches with M8 3-pin connector for V-slot

Cable length: 0.3 m



Mod. Operation Connection Voltage Output Max. current Max Load Protection
CSV-250N Reed 2 wires M8 male 3 pin 10 ÷ 110 V AC/DC - 250 mA 10 VA / 8 W None
CSV-262 Reed 3 wires M8 male 3 pin 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing
CSV-362 Magnetoresistive 3 wires M8 male 3 pin 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage
Note for 2-wire switch Mod. CSV-250N:
in case of polarity reversing the sensor will still be operating, but the LED diode won't turn on.