text.skipToContent text.skipToNavigation
Series D1

Series D1

Series
Accessories
there are no salable codes online
If you have entered Filters, try changing them or look in the "Configurator" tab
Full screen
CODING EXAMPLE - FIELDBUS VERSION
DM C 1 01 W R A - 2A2Q - 2A2BQH4AX4B - 3M2L3M2B2C - CS R
DM MODULAR ISLAND
C VALVE
C = VC Model
1 SIZE
1 = 10,5 mm
01 PROTOCOL
00 = Base without Fieldbus cover ***
01 = PROFIBUS
03 = CANopen
04 = Ethernet/IP

05 = Ethercat
06 = PROFINET
07 = IO-LINK (not configurable with input and and output modules)
W INTERFACE
O = without interface

W = WLAN
R MANUAL OVERRIDE
P = push button
R = with push and turn device
A SERVO-PILOT SUPPLY
A = internal

B = external
2A2Q INPUT AND OUTPUT MODULES
0 = without
A = 8 digital inputs M8
B = 16 digital inputs, terminal block connection
C = 2 analog inputs (config. 0-10V,±10V,0-20mA,4-20mA,±20mA) M12
D = 2 analog inputs (config. 0-10V,±10V,0-20mA,4-20mA,±20mA), terminal block
E = 2 inputs, BRIDGE M12
F = 2 inputs, BRIDGE, TERMINAL BLOCK CONNECTION
G = 2 inputs, RTD M12 (PT100, PT200, PT500, PT1000)
H = 2 inputs, RTD TERMINAL BLOCK CONNECTION (PT100, PT200, PT500, PT1000)
L = 2 inputs, TC M12 (THERMOCOUPLES)
M = 2 inputs, TC TERMINAL BLOCK CONNECTION (THERMOCOUPLES)
Q = 8 digital outputs M8
R = 16 digital outputs, terminal block connection
S = subnet expansion
T = 2 analog outputs (config. 0-10V,±10V,0-20mA, 4-20mA,±20mA), M12
U = 2 analog outputs (config. 0-10V,±10V,0-20mA,4-20mA,±20mA), terminal block (Push-in)
P = 8 digital inputs (4 M12 connectors)
Y = 8 digital outputs (4 M12 connectors)
W **** = closed base without I/O cover
2A2BQH4AX4B SUBBASES
Metric:
A = cartridge tube Ø4
B = cartridge tube Ø6
SUBBASE DIAPHRAGM #
Q = diaphragm on channels 1, 3, 5
R = diaphragm on channel 1
S = diaphragm on channels 3 and 5
WITH DIAPHRAGM AND EXTERNAL SERVO-PILOT SUPPLY #
QT = diaphragm on channels 1, 3, 5; 12/14 External
RT = diaphragm on channel 1; 12/14 External
ST = diaphragm on channels 3, 5; 12/14 External
WITH DIAPHRAGM AND INTEGRATED SILENCER #
QH = diaphragm on channels 1, 3, 5
RH = diaphragm on channel 1
SH = diaphragm on channels 3, 5
SUBBASE FOR ADDITIONAL FLOW #
X = supply (1) and exhausts (3, 5)
XH = supply (1) and exhausts (3, 5) with integrated silencer
INTERFACE SUBBASE FOR ADDITIONAL FLOW WITH EXTERNAL SERVO-PILOT SUPPLY #
XT = additional supply (1) and exhausts (3, 5)
FOR ELECTRICAL SUPPLY #
K = separation of electrical supply - supply (1) and exhausts (3, 5)
Z = separation of electrical supply - diaphragm on channel 1
# = these subbases are already provided with cartridges for tube Ø8, Ø5/16”

Inches:
A = cartridge tube Ø5/32”
G = cartridge tube Ø1/4”
J = subbase (D1) for servo-pilot control through solenoid valve (E;F) *
3M2L3M2B2C VALVES
M = 5/2 monostable
B = 5/2 bistable
C = 2x3/2 NC
A = 2x3/2 NO
G = 1x3/2 NC + 1x3/2 NO
V = 5/3 CC K = 5/3 CO
N = 5/3 CP
L = free position
W = position without valve

E = 3/2 NC for internal servo-pilot control (Line 1) **
F = 3/2 NC for external servo-pilot control **
D = 2x2/2 NC
H = 2x2/2 NO
R = 1x2/2 NC + 1x2/2 NO
CS TERMINAL PLATES
Cartridges on tube ports 1, 3, 5
Metric:
C = cartridge tube Ø8
CS = cartridge tube Ø8 3,5 with silencer


Inches:
C = cartridge tube Ø5/16”
CS = cartridge tube Ø5/16” 3,5 with silencers
R FIXING TYPE
= direct
R = DIN rail
* = The subbase is equipped with a cartridge Ø4 (Ø5/32”).
** = Solenoid valve for subbase model J.
*** = With the 00 protocol, the possible interface is 0, for example: DMC1000RA-...
**** = The closed base without I/O cover always has to be put after the other modules, if present. For example: DMC101WRA-2A2QW...
The choice of the cartridge made in the Terminal Plates section is also valid for the diaphragm and additional subbases.
QT, RT, ST, XT models have a 12/14 cartridge tube Ø4 (Ø5/32”).

FIELDBUS version DIMENSIONS


1-16/26  results
We think you are in United States.