text.skipToContent text.skipToNavigation
Series AP

Series AP

For the use with vacuum connect the line to port 2.
Series
Accessories
  • 1(current)
  • 2
22 Products found
Proport. valve 2-ways - AP-7211-FR2-U711
Series AP
Proport. valve 2-way - AP-7211-FR2-U712
Series AP
Valv. propo. - AP-7211-FW2-U711-OX2
Series AP
Proport. valve - AP-7211-FW2-U712-OX2
Series AP
Proporz. valves 2 ways - AP-7211-HR2-U711
Series AP
Proporz. valves 2 ways - AP-7211-HR2-U712
Series AP
Proport. valve - AP-7211-HW2-U711-OX2
Series AP
Proport. valve - AP-7211-HW2-U712-OX2
Series AP
Proport. valve - AP-7211-LE2-U712-OX2
Series AP
Dir.-op. pro. v. 2-way - AP-7211-LR2-U711
Series AP
Proporz. valves 2 ways - AP-7211-LR2-U712
Series AP
Proporz. valv. - AP-7211-LW2-U711-OX2
Series AP
  • 1(current)
  • 2
Full screen
Your configuration
CODING EXAMPLE
AP - 7 2 1 1 - L R 2 - U 7 11 OX2
AP SERIES
7 BODY
6 = size 16mm

7 = size 22mm
2 NUMBER OF WAYS
2 = 2-way
1 VALVE FUNCTION
1 = NC
1 PORTS
0 = M5 (size 16mm only)
1 = G1/8 (size 22mm only)

4 = with rear flanges (size 16mm only)
5 = with lower flanges

L = male hose adaptor (for body in PVDF only, size 16mm)
L ORIFICE
D = ø0,8 mm (size 16mm only)
F = ø1 mm

H = ø1,2 mm
L = ø1,6 mm

N = ø2 mm (size 22mm only)
Q = ø2,4 mm (size 22mm only)
R SEAL MATERIAL
R = NBR

W = FKM

E = EPDM
2 BODY MATERIAL
2 = brass

3 = PVDF (size 16mm only)
U ENCAPSULATING MATERIAL
G = PA (size 16mm only)

U = PET (size 22mm only)
7 SOLENOID DIMENSIONS
P = 16x26 DIN EN 175301-803-C (size 16mm only)

7 = 22x22 DIN 43650 B (size 22mm only)
11 SOLENOID VOLTAGE
H = 12 V DC 3 W (size 16mm only)
7 = 24 V DC 3 W (size 16mm only)

11 = 24 V DC 6,5 W (size 22mm only)
12 = 12 V DC 6,5 W (size 22mm only)
COIL ORIENTATION
= fastons opposite to pneumatic ports/same side of the outlet
5 = fastons towards pneumatic ports/same side of the inlet
OX2 VERSION
OX2 = version with ASTM G93-03 Certification Level B (FKM seals only)
= non-certified version

Series AP proportional valves - 22mm, body with threaded ports

AP01



Mod. Port 1 Port 2 Function Orifice Ø (mm) kv (l/min) Max pressure (bar) Max flow (Nl/min)
AP-7211-FR2-U7* G1/8 G1/8 2/2 NC 1 0,5 10 75
AP-7211-HR2-U7* G1/8 G1/8 2/2 NC 1,2 0,7 8 85
AP-7211-LR2-U7* G1/8 G1/8 2/2 NC 1,6 1,2 6 110
AP-7211-NR2-U7* G1/8 G1/8 2/2 NC 2 1,7 5 135
AP-7211-QR2-U7* G1/8 G1/8 2/2 NC 2,4 1,7 4 113
AP-7211-FW2-U7*OX2 G1/8 G1/8 2/2 NC 1 0,5 10 75
AP-7211-HW2-U7*OX2 G1/8 G1/8 2/2 NC 1,2 0,7 8 85
AP-7211-LW2-U7*OX2 G1/8 G1/8 2/2 NC 1,6 1,2 6 110
AP-7211-NW2-U7*OX2 G1/8 G1/8 2/2 NC 2 1,7 5 135
AP-7211-QW2-U7*OX2 G1/8 G1/8 2/2 NC 2,4 1,7 4 113
*choose the desired voltage

We think you are in United States.
Update your location?