text.skipToContent text.skipToNavigation
Series CFB

Series CFB

These solenoid valves have a solenoid protection system suitable to be used in particularly humid environments and in harsh conditions.
The system consists of two gaskets placed above and below the coil and a lock nut that integrates the upper gasket.
The standard diaphragm valve supplied is in NBR.
On demand it can be supplied in FKM or EPDM.
Series
there are no salable codes online
If you have entered Filters, try changing them or look in the "Configurator" tab
Full screen
Your configuration
Coding example
CFB - A 1 3 L - R 1 - B7 E
CFB SERIES
A OPERATION
A = indirect
B = direct with linked diaphragm
D = direct
E = indirect with coil for heavy-duty applications
1 NUMBER OF WAYS - POSITIONS
1 = 2/2-way - NO
2 = 2/2-way - NC
3 = 3/2-way - NC
3 CONNECTIONS
1 = G1/8
2 = G1/4
3 = G3/8
4 = G1/2
5 = G3/4
6 = G1
7 = G1 1/4
8 = G1 1/2
9 = G2
L ORIFICE DIAMETER
A = 1.4 mm
B = 2 mm
C = 2.5 mm
D = 2.8 mm
F = 4 mm
G = 6 mm
J = 8 mm
L = 11.5 mm
M = 13 mm
N = 13.5 mm
P = 18 mm
R = 26 mm
T = 32 mm
X = 45 mm
Z = 50 mm
R SEALS MATERIAL
R = NBR
W = FKM
E = EPDM (on demand)
1 BODY MATERIAL
1 = brass
2 = alimentary anti-limestone nickel-plated brass for high temperatures (on demand)
3 = alimentary nickel-plated brass (on demand)
B7 SOLENOID DIMENSION
B7 = 22 mm
B8 = 30 mm
B9 = 36 mm
E SOLENOID VOLTAGE
B = 24 V AC 50 Hz
D = 110 V AC 50/60 Hz
E = 230 V AC 50/60 Hz
2 = 12 V DC
3 = 24 V DC

Series CFB solenoid valve - indirectly op. for heavy-duty applications - 2/2 NC

* = choose the suitable solenoid according to the TABLE FOR THE COUPLING BETWEEN SOLENOID AND VALVES

EV48



Mod. Function Ports Ø Orifice (mm) Kv (m³/h) Pressure min÷max (bar) A B C F G H L SW SW1
CFB-E23L-R1-* 2/2 NC G3/8 11.5 2.6 0.1 ÷ 15 [ AC / DC ] 12 32.5 78.5 41.9 57 M8x0.75 30 24 13
CFB-E24N-R1-* 2/2 NC G1/2 13.5 3.5 0.1 ÷ 15 [ AC / DC ] 15 39.7 85.7 45 69 M8x0.75 30 30 13
CFB-E25P-R1-* 2/2 NC G3/4 18 5.8 0.2 ÷ 15 [ AC / DC ] 18 46.5 91.5 54.4 74 M8x0.75 30 34 13
CFB-E26R-R1-* 2/2 NC G1 26 9.5 0.2 ÷ 12 [ AC / DC ] 22.5 59.8 104.5 71 93 M8x0.75 30 45 13
CFB-E27T-R1-* 2/2 NC G1 1/4 32 12.5 0.4 ÷ 12 [ AC 50 Hz / DC ] - 0.4 ÷ 6 [ AC 60 Hz ] 27.5 73.5 130 86.6 111 G1/8 30 55 14
CFB-E28X-R1-* 2/2 NC G1 1/2 45 31 0.4 ÷ 10 [ AC 50 Hz / DC ] - 0.4 ÷ 3.5 [ AC 60 Hz ] 31 85 138.3 110 138 G1/8 30 62 14
CFB-E29Z-R1-* 2/2 NC G2 50 45 0.4 ÷ 10 [ AC 50 Hz / DC ] - 0.4 ÷ 3.5 [ AC 60 Hz ] 37.5 98.8 152 110 145 G1/8 30 75 14