text.skipToContent text.skipToNavigation
Mod. CSH

Mod. CSH

Series
Accessories
9 Products found
Mod. CSH
Mod. CSH
Mod. CSH
Mod. CSH
Mod. CSH
Mod. CSH
Mod. CSH
Mod. CSH
Mod. CSH
Full screen
Your configuration
SERIES CST, CSV, CSH CODING EXAMPLE
CS T 2 2 0 N 5 EX
CS SERIES
T TYPE OF SLOT:
T = T-slot
V = V-slot
H = H-slot
2 OPERATION:
2 = Reed NO
3 = Magnetoresistive
4 = Reed NC
5 = Hall effect
2 CONNECTIONS:
2 = 2 wires (Reed only)
3 = 3 wires
5 = 2 wires with M8 connector (Reed only)
6 = 3 wires with M8 connector
0 POWER SUPPLY VOLTAGE:
0 = 10 ÷ 110 V DC; 10 ÷ 230 V AC (PNP)
1 = 30 ÷ 110 V DC; 30 ÷ 230 V AC (PNP)
2 = 3 wires cst (PNP)
3 = 10 ÷ 30 V AC/DC (PNP)
4 = 10 ÷ 27 V DC (PNP)
N NOTE (CST/CSV-250N only):
N = according to norm
5 LENGTH OF THE CABLE:
= 2m (CST and CSV only)
2 = 2m (CSH only)
5 = 5m
EX
SERIES CSB, CSC, CSD CODING EXAMPLE
SERIES CSG CODING EXAMPLE

Magnetic proximity switches with 2 or 3 wire cable for H-slot



Mod. Operation Connection Voltage Output Max. current Max Load Protection L = cable legth
CSH-223-2 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-223-5 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 10 m
CSH-223-2EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-223-5EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 10 m
CSH-221-2 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-221-2EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-334-2 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-334-2EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-433-2 Reed NC 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-433-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-433-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-433-5EX Reed 3 wires 10 ÷ 30 V AC/DC- PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
Note for 2-wire switches Mod. CSH-223-2, CSH-223-5, CSH-221-2, CSH-221-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won't turn on.
 

Magnetic proximity switches with 2- or 3-wire cable for H-slot



Mod. Operation Connection Voltage Output Max. current Max Load Protection L = cable legth
CSH-223-2 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-223-5 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 10 m
CSH-223-2EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-223-5EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 10 m
CSH-221-2 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-221-2EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-334-2 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-334-2EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-433-2 Reed NC 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-433-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-433-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-433-5EX Reed 3 wires 10 ÷ 30 V AC/DC- PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
Note for 2-wire switches Mod. CSH-223-2, CSH-223-5, CSH-221-2, CSH-221-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won't turn on.
 

Magnetic proximity switches with 2 or 3 wire cable for H-slot



Mod. Operation Connection Voltage Output Max. current Max Load Protection L = cable legth
CSH-223-2 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-223-5 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 10 m
CSH-223-2EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-223-5EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 10 m
CSH-221-2 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-221-2EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-334-2 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-334-2EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-433-2 Reed NC 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-433-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-433-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-433-5EX Reed 3 wires 10 ÷ 30 V AC/DC- PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
Note for 2-wire switches Mod. CSH-223-2, CSH-223-5, CSH-221-2, CSH-221-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won't turn on.
 

Magnetic proximity switches with 2 or 3 wire cable for H-slot



Mod. Operation Connection Voltage Output Max. current Max Load Protection L = cable legth
CSH-223-2 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-223-5 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 10 m
CSH-223-2EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-223-5EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 10 m
CSH-221-2 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-221-2EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-334-2 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-334-2EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-433-2 Reed NC 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-433-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-433-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-433-5EX Reed 3 wires 10 ÷ 30 V AC/DC- PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
Note for 2-wire switches Mod. CSH-223-2, CSH-223-5, CSH-221-2, CSH-221-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won't turn on.
 

Magnetic proximity switches with 2 or 3 wire cable for H-slot



Mod. Operation Connection Voltage Output Max. current Max Load Protection L = cable legth
CSH-223-2 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-223-5 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 10 m
CSH-223-2EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-223-5EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 10 m
CSH-221-2 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-221-2EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-334-2 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-334-2EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-433-2 Reed NC 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-433-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-433-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-433-5EX Reed 3 wires 10 ÷ 30 V AC/DC- PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
Note for 2-wire switches Mod. CSH-223-2, CSH-223-5, CSH-221-2, CSH-221-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won't turn on.
 

Magnetic proximity switches with 2 or 3 wire cable for H-slot



Mod. Operation Connection Voltage Output Max. current Max Load Protection L = cable legth
CSH-223-2 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-223-5 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 10 m
CSH-223-2EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-223-5EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 10 m
CSH-221-2 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-221-2EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-334-2 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-334-2EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-433-2 Reed NC 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-433-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-433-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-433-5EX Reed 3 wires 10 ÷ 30 V AC/DC- PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
Note for 2-wire switches Mod. CSH-223-2, CSH-223-5, CSH-221-2, CSH-221-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won't turn on.
 

Magnetic proximity switches with 2- or 3-wire cable for H-slot



Mod. Operation Connection Voltage Output Max. current Max Load Protection L = cable legth
CSH-223-2 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-223-5 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 10 m
CSH-223-2EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-223-5EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 10 m
CSH-221-2 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-221-2EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-334-2 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-334-2EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-433-2 Reed NC 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-433-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-433-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-433-5EX Reed 3 wires 10 ÷ 30 V AC/DC- PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
Note for 2-wire switches Mod. CSH-223-2, CSH-223-5, CSH-221-2, CSH-221-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won't turn on.

Magnetic proximity switches with 2- or 3-wire cable for H-slot Mod. CSH



Mod. Operation Connection Voltage Output Max. current Max Load Protection L = cable legth
CSH-223-2 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-223-5 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 10 m
CSH-223-2EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-223-5EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 10 m
CSH-221-2 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-221-2EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m


Magnetic proximity switches with 2 or 3 wire cable for H-slot



Mod. Operation Connection Voltage Output Max. current Max Load Protection L = cable legth
CSH-223-2 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-223-5 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 10 m
CSH-223-2EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-223-5EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 10 m
CSH-221-2 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-221-2EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-334-2 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-334-2EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-433-2 Reed NC 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-433-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-433-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-433-5EX Reed 3 wires 10 ÷ 30 V AC/DC- PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
Note for 2-wire switches Mod. CSH-223-2, CSH-223-5, CSH-221-2, CSH-221-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won't turn on.
 

Magnetic proximity switches with 2- or 3-wire cable for H-slot Mod. CSH



Mod. Operation Connection Voltage Output Max. current Max Load Protection L = cable legth
CSH-223-2 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-223-5 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 10 m
CSH-223-2EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-223-5EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 10 m
CSH-221-2 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-221-2EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-334-2 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-334-2EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-433-2 Reed NC 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-433-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-433-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-433-5EX Reed 3 wires 10 ÷ 30 V AC/DC- PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
Note for 2-wire switches Mod. CSH-223-2, CSH-223-5, CSH-221-2, CSH-221-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won't turn on.
 

Magnetic proximity switches with 2 or 3 wire cable for H-slot



Mod. Operation Connection Voltage Output Max. current Max Load Protection L = cable legth
CSH-223-2 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-223-5 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 10 m
CSH-223-2EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-223-5EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 10 m
CSH-221-2 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-221-2EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-334-2 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-334-2EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-433-2 Reed NC 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-433-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-433-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-433-5EX Reed 3 wires 10 ÷ 30 V AC/DC- PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
Note for 2-wire switches Mod. CSH-223-2, CSH-223-5, CSH-221-2, CSH-221-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won't turn on.
 

Magnetic proximity switches with 2 or 3 wire cable for H-slot



Mod. Operation Connection Voltage Output Max. current Max Load Protection L = cable legth
CSH-223-2 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-223-5 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 10 m
CSH-223-2EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-223-5EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 10 m
CSH-221-2 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-221-2EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-334-2 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-334-2EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-433-2 Reed NC 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-433-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-433-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-433-5EX Reed 3 wires 10 ÷ 30 V AC/DC- PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
Note for 2-wire switches Mod. CSH-223-2, CSH-223-5, CSH-221-2, CSH-221-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won't turn on.
 

Magnetic proximity switches with 2- or 3-wire cable for H-slot



Mod. Operation Connection Voltage Output Max. current Max Load Protection L = cable legth
CSH-223-2 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-223-5 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 10 m
CSH-223-2EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-223-5EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 10 m
CSH-221-2 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-221-2EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-334-2 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-334-2EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-433-2 Reed NC 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-433-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-433-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-433-5EX Reed 3 wires 10 ÷ 30 V AC/DC- PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
Note for 2-wire switches Mod. CSH-223-2, CSH-223-5, CSH-221-2, CSH-221-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won't turn on.
 

Magnetic proximity switches with 2 or 3 wire cable for H-slot



Mod. Operation Connection Voltage Output Max. current Max Load Protection L = cable legth
CSH-223-2 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-223-5 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 10 m
CSH-223-2EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-223-5EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 10 m
CSH-221-2 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-221-2EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-334-2 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-334-2EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-433-2 Reed NC 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-433-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-433-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-433-5EX Reed 3 wires 10 ÷ 30 V AC/DC- PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
Note for 2-wire switches Mod. CSH-223-2, CSH-223-5, CSH-221-2, CSH-221-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won't turn on.
 

Magnetic proximity switches with 2 or 3 wire cable for H-slot



Mod. Operation Connection Voltage Output Max. current Max Load Protection L = cable legth
CSH-223-2 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-223-5 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 10 m
CSH-223-2EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-223-5EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 10 m
CSH-221-2 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-221-2EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-334-2 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-334-2EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-433-2 Reed NC 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-433-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-433-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-433-5EX Reed 3 wires 10 ÷ 30 V AC/DC- PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
Note for 2-wire switches Mod. CSH-223-2, CSH-223-5, CSH-221-2, CSH-221-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won't turn on.
 

Magnetic proximity switches with 2 or 3 wire cable for H-slot



Mod. Operation Connection Voltage Output Max. current Max Load Protection L = cable legth
CSH-223-2 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-223-5 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 10 m
CSH-223-2EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-223-5EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 10 m
CSH-221-2 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-221-2EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-334-2 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-334-2EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-433-2 Reed NC 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-433-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-433-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-433-5EX Reed 3 wires 10 ÷ 30 V AC/DC- PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
Note for 2-wire switches Mod. CSH-223-2, CSH-223-5, CSH-221-2, CSH-221-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won't turn on.
 

Magnetic proximity switches with 2- or 3-wire cable for H-slot

Cable length: 0,3 m



Mod. Operation Connection Voltage Output Max. current Max Load Protection
CSH-253 Reed NO 2 wires M8 male 3 pin 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing
CSH-253EX Reed NO 2 wires M8 male 3 pin 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing
CSH-263 Reed NO 3 wires M8 male 3 pin 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing
CSH-263EX Reed NO 3 wires M8 male 3 pin 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing
CSH-364 Magnetoresistive 3 wires M8 male 3 pin 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage
CSH-364EX Magnetoresistive 3 wires M8 male 3 pin 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage
CSH-463 Reed NC 3 wires M8 male 3 pin 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing
CSH-463EX Reed NC 3 wires M8 male 3 pin 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing
Note for 2-wire switch Mod. CSH-253:
in case of polarity reversing the sensor will still be operating, but LED diode won't turn on.

Magnetic proximity switches with 2- or 3-wire cable for H-slot



Mod. Operation Connection Voltage Output Max. current Max Load Protection L = cable legth
CSH-223-2 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-223-5 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 10 m
CSH-223-2EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-223-5EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 10 m
CSH-221-2 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-221-2EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-334-2 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-334-2EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-433-2 Reed NC 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-433-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-433-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-433-5EX Reed 3 wires 10 ÷ 30 V AC/DC- PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
Note for 2-wire switches Mod. CSH-223-2, CSH-223-5, CSH-221-2, CSH-221-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won't turn on.
 

Magnetic proximity switches with 2- or 3-wire cable for H-slot



Mod. Operation Connection Voltage Output Max. current Max Load Protection L = cable legth
CSH-223-2 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-223-5 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 10 m
CSH-223-2EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-223-5EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 10 m
CSH-221-2 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-221-2EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-334-2 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-334-2EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-433-2 Reed NC 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-433-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-433-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-433-5EX Reed 3 wires 10 ÷ 30 V AC/DC- PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
Note for 2-wire switches Mod. CSH-223-2, CSH-223-5, CSH-221-2, CSH-221-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won't turn on.
 

Magnetic proximity switches with 2 or 3 wire cable for H-slot



Mod. Operation Connection Voltage Output Max. current Max Load Protection L = cable legth
CSH-223-2 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-223-5 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 10 m
CSH-223-2EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-223-5EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 10 m
CSH-221-2 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-221-2EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-334-2 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-334-2EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-433-2 Reed NC 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-433-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-433-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-433-5EX Reed 3 wires 10 ÷ 30 V AC/DC- PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
Note for 2-wire switches Mod. CSH-223-2, CSH-223-5, CSH-221-2, CSH-221-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won't turn on.
 

Magnetic proximity switches with 2 or 3 wire cable for H-slot



Mod. Operation Connection Voltage Output Max. current Max Load Protection L = cable legth
CSH-223-2 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-223-5 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 10 m
CSH-223-2EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-223-5EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 10 m
CSH-221-2 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-221-2EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-334-2 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-334-2EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-433-2 Reed NC 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-433-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-433-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-433-5EX Reed 3 wires 10 ÷ 30 V AC/DC- PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
Note for 2-wire switches Mod. CSH-223-2, CSH-223-5, CSH-221-2, CSH-221-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won't turn on.
 

Magnetic proximity switches with 2 or 3 wire cable for H-slot



Mod. Operation Connection Voltage Output Max. current Max Load Protection L = cable legth
CSH-223-2 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-223-5 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 10 m
CSH-223-2EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-223-5EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 10 m
CSH-221-2 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-221-2EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-334-2 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-334-2EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-433-2 Reed NC 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-433-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-433-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-433-5EX Reed 3 wires 10 ÷ 30 V AC/DC- PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
Note for 2-wire switches Mod. CSH-223-2, CSH-223-5, CSH-221-2, CSH-221-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won't turn on.
 

Magnetic proximity switches with 2 or 3 wire cable for H-slot



Mod. Operation Connection Voltage Output Max. current Max Load Protection L = cable legth
CSH-223-2 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-223-5 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 10 m
CSH-223-2EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-223-5EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 10 m
CSH-221-2 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-221-2EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-334-2 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-334-2EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-433-2 Reed NC 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-433-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-433-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-433-5EX Reed 3 wires 10 ÷ 30 V AC/DC- PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
Note for 2-wire switches Mod. CSH-223-2, CSH-223-5, CSH-221-2, CSH-221-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won't turn on.
 

Magnetic proximity switches with 2 or 3 wire cable for H-slot



Mod. Operation Connection Voltage Output Max. current Max Load Protection L = cable legth
CSH-223-2 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-223-5 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 10 m
CSH-223-2EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-223-5EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 10 m
CSH-221-2 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-221-2EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-334-2 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-334-2EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-433-2 Reed NC 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-433-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-433-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-433-5EX Reed 3 wires 10 ÷ 30 V AC/DC- PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
Note for 2-wire switches Mod. CSH-223-2, CSH-223-5, CSH-221-2, CSH-221-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won't turn on.
 

Magnetic proximity switches with 2 or 3 wire cable for H-slot



Mod. Operation Connection Voltage Output Max. current Max Load Protection L = cable legth
CSH-223-2 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-223-5 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10 Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 10 m
CSH-223-2EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-223-5EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-223-10EX Reed 2 wires 10 ÷ 30 V AC/DC - 250 mA 10 VA / 8 W Against polarity reversing 10 m
CSH-221-2 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5 Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-221-2EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-221-5EX Reed 2 wires 30 ÷ 230 V AC - 30 ÷ 110 V DC - 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-233-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-233-5EX Reed 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-334-2 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-334-2EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 2 m
CSH-334-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 250 mA 6 W Against polarity reversing and overvoltage 5 m
CSH-433-2 Reed NC 3 wires 10 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing and overvoltage 2 m
CSH-433-5 Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CSH-433-2EX Reed 3 wires 10 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CSH-433-5EX Reed 3 wires 10 ÷ 30 V AC/DC- PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
Note for 2-wire switches Mod. CSH-223-2, CSH-223-5, CSH-221-2, CSH-221-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won't turn on.
 

We think you are in United States.