text.skipToContent text.skipToNavigation
Series MX-PRO

Series MX-PRO

M8 4-POLE MALE CONNECTOR
  • Pin 1: +24 V DC (Power supply);
  • Pin 2: Command analogical signal 0-10 V DC or 4-20 mA;
  • Pin 3: 0 V (Ground) common also for the command signal;
  • Pin 4: Output analogical signal (according to the regulated pressure).

5 Red LED
6 Green LED
Series
Accessories
there are no salable codes online
If you have entered Filters, try changing them or look in the "Configurator" tab
Full screen
Your configuration
CODING EXAMPLE
MX 2 - 1/2 - R CV 2 0 4 - LH - OX1
MX SERIES
2 SIZE:
2 = G1/2
1/2 PORTS:
1/2 = G1/2
R FUNCTIONING:
R = pressure regulator
M = Manifold pressure regulator

V = flow valve
W = Manifold flow valve
CV COMMAND:
CV = electrical command 0-10 V DC (regulator only)
CA = electrical command 4-20 mA (regulator only)

XV = electrical command 0-10 V DC with external servo pilot supply
XA = electrical command 4-20 mA DC with external servo pilot supply
EV = electrical command 0-10 V DC with external servo pilot supply
EA = electrical command 4-20 mA with external servo pilot supply
2 REGULATOR SETTING RANGE:
1 = working pressure 0,15 ÷ 3 bar
2 = working pressure 0,5 ÷ 10 bar *
3 = working pressure 0,05 ÷ 1 bar
4 = working pressure 0,35 ÷ 7 bar
VALVE SETTING RANGE:
7 = flow valve
0 DESIGN TYPE:
0 = relieving (regulator only)
1 = without relieving
4 PRESSURE GAUGE:
0 = without pressure gauge, with threaded port for gauges (for OX1 version)
2 = with built-in pressure gauge 0-6 bar (regulator only)

3 = with built-in pressure gauge 0-10 bar (regulator only)
4 = with built-in pressure gauge 0-12 bar (regulator only)
LH FLOW DIRECTION:
= from left to right (standard)
LH = from right to left
OX1 = suitable for use with oxygen

* For the configurations with the pressure regulation range of 10 bar in the OX1 version, the version with external servo pilot air supply is mandatory.
Further details about the assembly of a single component with fixing flanges or wall-mounting can be found in the AIR TREATMENT catalogue, section SERIES MX ASSEMBLED FRL.

Series MX-PRO proportional pressure regulator - Single version

DRAWING NOTES:
** = in the versions with external servo pilot supply only (MX2-1/2-REV... and MX2-1/2-REA...)
* = only in the OX1 versions with relieving



Mod. Electrical command Setting range Pressure gauge
MX2-1/2-R**100OX1 0-10 V DC/4-20 mA 0,15 ÷ 3 bar without pressure gauge
MX2-1/2-R**1#2 0-10 V DC/4-20 mA 0,15 ÷ 3 bar with built-in pressure gauge 0-6
MX2-1/2-R**2#0 0-10 V DC/4-20 mA 0,5 ÷ 10 bar without pressure gauge
MX2-1/2-R**2#4 0-10 V DC/4-20 mA 0,5 ÷ 10 bar with built-in pressure gauge 0-12
MX2-1/2-R**3#0 0-10 V DC/4-20 mA 0,05 ÷ 1 bar without pressure gauge
MX2-1/2-R**4#0 0-10 V DC/4-20 mA 0,35 ÷ 7 bar without pressure gauge
MX2-1/2-R**4#3 0-10 V DC/4-20 mA 0,15 ÷ 3 bar with built-in pressure gauge 0-10
MX2-1/2-R**100OX1 0-10 V DC/4-20 mA 0,15 ÷ 3 bar without pressure gauge
MX2-1/2-R**300OX1 0-10 V DC/4-20 mA 0,05 ÷ 1 bar without pressure gauge
MX2-1/2-R**400OX1 0-10 V DC/4-20 mA 0,35 ÷ 7 bar without pressure gauge
MX2-1/2-RE*200OX1 0-10 V DC/4-20 mA 0,5 ÷ 10 bar without pressure gauge
TABLE NOTES:
* = versions with or without external pilot supply
# = versions with our without relieving
LH = add LH at the end of the code for air inlet from the right to the left

We think you are in United States.
Update your location?