Interface with: PROFIBUS, CANopen, EtherNet/IP, PROFINET, EtherCAT.
Can be integrated with I/O Modules.
Series CX4 multi-serial module can interface with the most common fieldbus protocols, like Profibus-DP, CANOpen, EtherCAT, EtherNet/IP, PROFINET. The possibility to enlarge with both Digital and Analog I/O modules, the acquisition of signals coming from Bridge, RTD or TC sensors, the resolution of up to 24 bit and the high number of manageable signals make it particularly suitable for different needs.

Connectable with PC through MicroUSB port, check and configuration of connected components by means of UVIX software. Configuration through Fieldbus. By means of a mechanical interface connection it is used in combination with the Series D valve islands.
Series
Accessories
there are no salable codes online
If you have entered Filters, try changing them or look in the "Configurator" tab
Number of digital outputs 128
Number of analogic outputs 16
Number of digital inputs 128
Number of analogic inputs 16
Maximum input absorption 1,5 A
Maximum output absorption 2,5 A
Supply voltage 24 V DC +/-10% logic supply
24 V DC +/-10% power supply
Protection overload and reverse polarity
Protection class IP65 (IP20 in case of module I/O with terminal block)
Conform with standards EN-61131-2
Operating temperature 0-50°C
Material polymer
Full screen
Your configuration
CODING EXAMPLE
CX 4 01 W - 2A2Q - R
CX SERIES
4 VERSION
4 = CX4
01 PROTOCOL
00 = Base closed without Fieldbus cover
01 = PROFIBUS
03 = CANopen
04 = EtherNet/IP
05 = EtherCAT
06 = PROFINET
W INTERFACE
0 = No interface
W = WLAN
2A2Q INPUT/OUTPUT MODULES
0 = no module
A = 8 digital inputs M8
B = 16 digital inputs terminal block (Push-in) connection
C = 2 analog inputs (config. 0-10V, ±10V, 0-20mA, 4-20mA, ±20mA) M12
D = 2 analog inputs (config. 0-10V, ±10V, 0-20mA, 4-20mA, ±20mA) terminal block (Push-in) connection
E = 2 BRIDGE inputs M12
F = 2 BRIDGE inputs terminal block (Push-in) connection
G = 2 RTD inputs M12 (PT100, PT200, PT500, PT1000)
H = 2 RTD inputs terminal block (Push-in) connection (PT100, PT200, PT500, PT1000)
L = 2 TCM12 inputs (THERMOCOUPLES)
M = 2 TC inputs terminal block (Push-in) connection (THERMOCOUPLES)
Q = 8 digital outputs M8
R = 16 digital outputs terminal block (Push-in) connection
S = subnet expansion
T = 2 Analog outputs (config. 0-10V,±10V,0-20mA, 4-20mA,±20mA), M12
U = 2 Analog outputs (config. 0-10V,±10V,0-20mA,4-20mA,±20mA), terminal block
P = 8 digital inputs (4 M12 connectors)
Y = 8 digital outputs (4 M12 connectors)
W ** = Closed base without I / O cover
R FIXING TYPE
= direct
R = DIN rail
** = The closed base without I / O cover must always be placed after the other modules if present ex: CX401W-2A2W-R...