text.skipToContent text.skipToNavigation
Series HC

Series HC

Multipole connection with 25 or 37 pins
Valve functions: 2x2/2, 2x3/2, 5/2, 5/3 CC
In applications which are subject to washing or operate in particularly dirty environments, having a specific solution represents a distinct advantage. With the Series HC it is possible to exploit the subbase and relative perimetric seal to close the passage window of all tubings. In this way the external environment is isolated from the internal part of the cabinet, guaranteeing a high protection level against solid and liquid particles that, upon entering, may damage the components.

All pneumatic connections are immediately available avoiding operations for the installation of panel mount fittings. Series HC uses the same valve functions as those available in Series HN.

Thanks to a particularly flexible use of the valve positions, different configurations can be realized (further details can be found on the following pages regarding the correct management of electrical signals).
Series
Accessories
there are no salable codes online
If you have entered Filters, try changing them or look in the "Configurator" tab

GENERAL DATA

PNEUMATIC SECTION
Valve construction spool with seals
Valve functions 5/2 monostable and bistable
5/3 CC
2 x 2/2 NO
2 x 2/2 NC
1 x 2/2 NC+ 1 x NO
2 x 3/2 NC
2 x 3/2 NO
1 x 3/2 NC+ 1 x 3/2 NO
Materials spool in aluminium
spool seals in HNBR
other seals in NBR
cartridges in brass
body and end covers in technopolymer
subbases in aluminium
Connections Inlets 2 and 4, size 10.5mm: M7, tube Ø 4, tube Ø 6
Inlets 2 and 4, size 21mm: G1/4, tube Ø 6, tube Ø 8, tube Ø 10

Supply 1: G3/8, tube Ø 8, tube Ø 10, tube Ø 12
Supply 12/14: M7, tube Ø 6 (6512 6-M7-M)

Exhausts 3 and 5: G1/4, tube Ø 10 (6512 10-1/4-M)
Exhausts 82/84: M7, silencer (2931 M7)
Temperature 0 ÷ 50°C
Air specifications Filtered compressed air, non lubricated, class 6.4.4 according to ISO 8573-1:2010.
If lubrication is necessary, please only use oils with maximum viscosity of 32 Cst
and the version with external servo-pilot supply.
The servo-pilot supply air quality class must be 6.4.4 according to ISO 8573-1:2010 (do not lubricate).
Valve sizes 10.5mm
21mm
Working pressure -0.9 ÷ 10 bar
Pilot pressure 3 ÷ 7 bar
4.5 ÷ 7 bar (with working pressure exceeding 6 bar for the versions 2x2/2 and 2x3/2)
Flow rate 400 Nl/min (10.5mm)
700 Nl/min (21mm)
Mounting position any position
Protection class IP65
ELECTRICAL SECTION
Type of Sub-D connector
Max. absorption
Supply voltage
Max. number of coils to operate
Valve signalling

Full screen
CODING EXAMPLE - MULTIPOLE VERSION
In presence of identical consequent codes both for the subbases as for the valves you need to substitute the letter with the number.
Ex: HC5H-03A-TGGGGTGSTGGG-MBBCCBMZVMMM-G is converted to HHC5H-03A-T4GTGST3G-M2B2CBMZV3M-G.
M2B2CBMZV3M G
M2B2CBMZV3M SOLENOID VALVES
Size 1 and 2:
M = 5/2 Monostable
B = 5/2 Bistable
V = 5/3 CC
C = 2 x 3/2 NC
A = 2 x 3/2 NO
G = 1 x 3/2 NC + 1 x 3/2 NO
E = 2 x 2/2 NC
F = 2 x 2/2 NO
I = 1 x 2/2 NC + 1 x 2/2 NO
L = free position
SOLENOID VALVE + PRESSURE REGULATOR
on channel 1, Size 2:
N = 5/2 Monostable
P = 5/2 Bistable
Q = 5/3 CC
R = 2 x 3/2 NC
S = 2 x 3/2 NO
T = 1 x 3/2 NC + 1 x 3/2 NO
U = 2 x 2/2 NC
X = 2 x 2/2 NO
Y = 1 x 2/2 NC + 1 x 2/2 NO
PLATES:
Z = plate for supplementary exhaust
K = plate for supplementary supply
G CONNECTIONS:


Internal servo-pilot
Internal servo-pilot and silencers
External servo-pilot
External servo-pilot and silencers



If the connection on the right side only,
add X at the end of the code.
For example: GX (Internal servo-pilot,
silencers, fitting tube ø 8)

The connections on the sides that are not
used are equipped with closing taps.

Supply fitting (1)
Thread ø 8 ø 10 ø 12
A E I P
- G M R
B F L Q
- H N S
Fitting ø 10 on exhausts 3/5
Fitting ø 6 on servo-pilot 12/14

If the connection on the left side only,
dd K at the end of the code.
For example: GK


A and B versions are equipped with taps
on the left side and on the right one.










If the connection is on both sides,
add W at the end of the code.
For example: GW
CODING - MULTIPOLE VERSION
SIZE 1 2 5
SIZE ( 1 ) ELECTRICAL
CONNECTION
( 2 ) CONNECTION ( 3 ) VALVE DIMENSION
and CONNECTION
Size 1
( 4 ) SOLENOID VALVES
Size 1 and 2
( 5 ) CONNECTIONS / SERVO PILOT
Threaded (low side)
( 6 ) ACCESSORIES ( 7 )
1 M 000 F M A G
2 H 03A G B B
5 05A L V CONNECTIONS / SERVO PILOT
Fittings tube Ø 8 (low side)
10A VALVE DIMENSION
and CONNECTION
Size 2
C E
15A M A F
20A N G G
25A P E H
03R T F CONNECTIONS / SERVO PILOT
Fittings tube Ø 10 (low side)
05R S I I
10R L L
15R SOLENOID VALVE +
PRESSURE REGULATOR
channel 1, size 2
M
20R N N
25R P CONNECTIONS / SERVO PILOT
Fittings tube Ø 12 (supply)
4XA Q P
4XR R Q
9XA S R
9XR T S
CXA U See the notes at the end
of the coding example
X
Y
PLATES
Z
K
CODING EXAMPLE OF SINGLE VALVE (Spare part)
CODING EXAMPLE OF SUBBASES - Accessories
HC A 1 R 10
HC SERIES
A TYPE:
A = accessories
1 SIZE:
1 = 10.5
R TYPE OF ACCESSORY:
R = subbase for multipole connection
G = seal
10 VALVE POSITIONS:
4 = 4
6 = 6
8 = 8
10 = 10
12 = 12
14 = 14
16 = 16
20 = 20
24 = 24
28 = 28
32 = 32

MULTIPOLE version 25 and 37 pin - DIMENSIONS


Adapter cable, M8 3-pin male - M12 4-pin female

Protection class: IP69K


We think you are in United States.
Update your location?