text.skipToContent text.skipToNavigation
Series 3 Plug-In

Series 3 Plug-In

Plug-In system for Series 3 solenoid valves, G1/8 port.
Valve functions: 2x3/2, 5/2 and 5/3-way CO CC CP.
Multipole with a 25-pin Sub-D connector.
It can interface with all major serial communication protocols.
The Multipole version of Series 3 Plug-In valve island can be easily installed thanks to the front position of the Sub-D connector. The accessories of the new connection system to the Series CX serial nets enable to handle up a multipole valve island by means of a Sub-D connector or through a node integrated in the island.
The modularity of the electric and pneumatic parts allows to install up to a maximum of 22 solenoids on 22 valve positions.

The electric and pneumatic modules have 2- and 3-position modularity. To optimize the signals distribution, electric modules are available for monostable and bistable valves. The pneumatic modularity enables the creation of zones with differentiated pressure.
 
Series
there are no salable codes online
If you have entered Filters, try changing them or look in the "Configurator" tab
PNEUMATIC SECTION
Valve construction Spool type with seals
Valve functions 5/2 - 5/3 CC - 5/3 CO - 5/3 CP - 2x3/2 NO - 2x3/2 NC - 1 3/2 NO + 1 3/2 NC
Materials AL body, stainless steel spool, NBR seals, technopolymer
Mounting Through-out holes in the manifold
Ports Valve = G1/8 - manifold = G3/8
Installation In any position
Operating temperature from 0°C to 60°C (with dry air at -20°C)
Nominal flow rate Qn 700 Nl/min
Nominal diameter 7 mm
Fluid Filtered air, class 7.4.4 according to ISO 8573-1-2010, without lubrication. If lubricated air is used, it is recommended to use ISO VG32 oil, and to never interrupt the lubrication.
ELECTRICAL SECTION - MULTIPOLE VERSION
Type of connection Multipole 25-pin male Sub-D
Supply voltage 24 V DC +/- 10%
Max number of solenoids 22 on 22 valve positions
Signalling Yellow LED
Duty cycle ED 100%
Protection class IP65
ELECTRICAL SECTION - FIELDBUS VERSION
General characteristics See the section about the Series CX multi-serial module
Max. absorption Digital outputs/analogic inputs and outputs 3A
digital/analogic inputs 3 A
Voltage tolerances Logic supply 24 V DC +/- 10%
power supply 24 V DC +/- 10%