FIELDBUS and IO-LINK VERSION
Series D5
The new CX4 fieldbus module integrated in the Series D valve island enables to interface with the most common fieldbus protocols. Besides managing the pneumatic part (the same as the Multipole version) different kinds of electric modules can be managed. With this configuration it is possible to enlarge the pneumatic part up to a maximum of 64 valve positions with double command and the electric part up to 128 digital inputs and 128 digital outputs, besides 16 analog inputs and 16 analog outputs. Besides the standard voltage and current versions, the analog modules are also available in 2-channel Bridge, RTD and TC versions.
Also in the IO-Link version, the interface module is part of the Series CX4.
In this configuration, the I/O Modules cannot be integrated in the island, a maximum of 64 coils can be managed on 32 valve positions.
Also in the IO-Link version, the interface module is part of the Series CX4.
In this configuration, the I/O Modules cannot be integrated in the island, a maximum of 64 coils can be managed on 32 valve positions.
Series
Accessories
there are no salable codes online
If you have entered Filters, try changing them or look in the "Configurator" tab
there are no salable codes online
Look in the "Accessory" tab for the Configurator
addtocart.popup.message.success
The requested quantity is partially confirmed
Product {0} is already in your cart with quantity {1}. You can update the quantity from cart page.
Product is not active
The product could not be added to the cart due to insufficient stock
Quantity must be greater than zero
Min allowed quantity for product {0} is {1}
Max allowed quantity for product {0} is {1}
Pack size for product {0} is {1}
It is not possible to add the product with code {0} to this cart
An error occurred, please try again later or contact customer support
CODING EXAMPLE - FIELDBUS VERSION
The choice of the cartridge made in the Terminal Plates section is also valid for the diaphragm and additional sub-bases
**The closed base without I/O cover must always be placed after the other modules if present e.g .: DMC501WRA-2A2QW ...
**The closed base without I/O cover must always be placed after the other modules if present e.g .: DMC501WRA-2A2QW ...
DM | C | 5 | 01 | W | R | A | 2A2Q | 2CD2NSHDN | 2MBLC2B | F | R |
DM | MODULAR ISLAND | |
C |
VALVE C= VC Model |
|
5 |
SIZE: 5 = 10,5mm (D1) + 16 mm (D2) |
|
01 |
PROTOCOL 00 = Base without Fieldbus 05 = Ethercat 01 = PROFIBUS 06 = PROFINET 03 = CANopen 07 = IO-LINK (cannot be configured with input and output modules) 04 = Ethernet/IP |
|
W |
INTERFACE O = without interface W = WLAN |
|
R |
MANUAL OVERRIDE P = push button R = with push and turn device |
|
A |
SERVO-PILOT SUPPLY A = internal B = external |
|
2A2Q |
INPUT AND OUTPUT MODULES 0 = without A = 8 Digital inputs M8 B = 16 Digital inputs, terminal block connection C = 2 Analog inputs (config. 0-10V,±10V,0-20mA,4-20mA,±20mA) M12 D = 2 Analog inputs (config. 0-10V,±10V,0-20mA,4-20mA,±20mA), terminal block E = 2 Inputs, BRIDGE M12 F = 2 Inputs, BRIDGE, TERMINAL BLOCK CONNECTION G = 2 Inputs, RTD M12 (PT100, PT200, PT500, PT1000) H = 2 Inputs, RTD TERMINAL BLOCK CONNECTION (PT100, PT200, PT500, PT1000) L = 2 Inputs, TC M12 (THERMOCOUPLES) M = 2 Inputs, TC TERMINAL BLOCK CONNECTION (THERMOCOUPLES) Q = 8 Digital outputs M8 R = 16 Digital outputs, terminal block connection T = 2 Analog outputs (config. 0-10V,±10V,0-20mA, 4-20mA,±20mA), M12 U = 2 Analog outputs (config. 0-10V,±10V,0-20mA,4-20mA,±20mA), terminal block W** = Closed base without I/O cover |
|
2CD2NSHDN |
SUBBASES Metric: Inches: N = Cartridges tube Ø4 (D1) N = Cartridges tube Ø 5/32" M = Cartridges tube Ø6 (D1) G = Cartridges tube Ø 1/4" B = Cartridges tube Ø6 (D2) L = Cartridges tube Ø 1/4" C = Cartridges tube Ø8 (D2) P = Cartridges tube Ø 3/8" D = Cartridges tube Ø10 (D2) SUBBASE DIAPHRAGM Q = Diaphragm on channels 1, 3, 5 R = Diaphragm on channel 1 S = Diaphragm on channels 3 and 5 WITH DIAPHRAGM AND EXTERNAL SERVO-PILOT SUPPLY QT = Diaphragm on channels 1, 3, 5; 12/14 External RT = Diaphragm on channel 1; 12/14 External ST = Diaphragm on channels 3, 5; 12/14 External WITH DIAPHRAGM AND INTEGRATED SILENCER QH = Diaphragm on channels 1, 3, 5 RH = Diaphragm on channel 1 SH = Diaphragm on channels 3, 5 SUBBASE FOR ADDITIONAL FLOW X = Supply (1) and exhausts (3, 5) XH = Supply (1) and exhausts (3, 5) with integrated silencer INTERFACE SUBBASE FOR ADDITIONAL FLOW WITH EXTERNAL SERVO-PILOT SUPPLY XT = Additional supply (1) and exhausts (3, 5) FOR POWER SUPPLY K = separation of power supply |
|
2MBLC2B |
VALVES M = 5/2 Monostable V = 5/3 CC B = 5/2 Bistable K = 5/3 CO C = 2x3/2 NC N = 5/3 CP A = 2x3/2 NO L = Free position G = 2x3/2 (NC+NO) |
|
F |
TERMINAL PLATES Fittings on tube ports 1, 3, 5 C = Cartridge tube Ø 8 CS = Cartridge tube Ø 8 and external silencer (2939-8) D = Cartridge tube Ø 10 DS = Cartridge tube Ø 10 and external silencer (2939-10) E = Cartridge tube Ø 12 ES = Cartridge tube Ø12 and external silencer (2939-10) F = Cartridge tube Ø 14 |
C = Cartridge tube Ø8" CS = Cartridge tube Ø8" 3,5 with silencier P = Cartridge tube Ø3/8" R = Cartridge tube Ø1/2" |
R |
FIXING TYPE = direct R = DIN rail |
1-16/22 results