Pneumatically and electropneumatically operated valves
Series 8
2/2-way - Normally Closed (NC)
3/2-way - Normally Closed (NC)
3/2-way - Normally Closed (NC)
The Series 8 enlarges the range of versions available with the cartridge valve directly integrated in an anodized aluminium body comprising also the pilot solenoid valve. The new bodies enable to have pneumatically operated versions with external piloting or electropneumatically operated versions with both external and internal piloting.
1-6/6 results
Series
there are no salable codes online
If you have entered Filters, try changing them or look in the "Configurator" tab
addtocart.popup.message.success
The requested quantity is partially confirmed
Product {0} is already in your cart with quantity {1}. You can update the quantity from cart page.
Product is not active
The product could not be added to the cart due to insufficient stock
Quantity must be greater than zero
Min allowed quantity for product {0} is {1}
Max allowed quantity for product {0} is {1}
Pack size for product {0} is {1}
It is not possible to add the product with code {0} to this cart
An error occurred, please try again later or contact customer support
TECHNICAL SPECIFICATIONS | |
Function | 2/2 NC – 3/2 NC |
Operation | Pneumatic or electropneumatic |
Pneumatic connections | G1/8 – G1/4 – G3/8 |
Nominal diameter | 5 … 9 mm |
Flow coefficient kv (l/min) | 6.5 … 23 |
Nominal flow | 420 … 1480 Nl/min (air at 6 bar ∆P 1 bar) |
Operating pressure | 3 ÷ 6 bar (0 ÷ 6 bar with external pilot supply) |
External pilot pressure | 3 ÷ 6 bar |
Operating temperature | 0 ÷ 50 °C |
Fluid | Filtered air class 5.4.4 according to ISO 8573-1 (oil viscosity max. 32 cSt), inert gases |
Response time | ON <10 ms - OFF <10 ms |
Installation | Any position |
MATERIALS IN CONTACT WITH FLUID | |
Body | Aluminium |
Seals | FKM |
Internal parts | Aluminium – brass |
ELECTRICAL SPECIFICATIONS | |
Voltage | 24 V DC – other voltages on demand |
Voltage tolerance | Size 1 = ±10% - Size 2 and 3 = -10% +15% |
Power consumption | Size 1 = 1.3 W (inrush) 0.25 W (holding) – Size 2 and 3 = 2 W |
Duty cycle | ED 100% |
Electrical connection | Connectors – 300 mm flying leads |
Protection class | Size 1 = IP50 – Size 2 and 3 = IP65 (with connector) |
addtocart.popup.message.success
The requested quantity is partially confirmed
Product {0} is already in your cart with quantity {1}. You can update the quantity from cart page.
Product is not active
The product could not be added to the cart due to insufficient stock
Quantity must be greater than zero
Min allowed quantity for product {0} is {1}
Max allowed quantity for product {0} is {1}
Pack size for product {0} is {1}
It is not possible to add the product with code {0} to this cart
An error occurred, please try again later or contact customer support
Coding example
8 | 10 | C3 | 4 | 04 | - | F1 | 3 | 1 | Y | - | N | 00 | 2C | C014 |
8 | SERIES |
10 |
SIZE 10 = size 1 20 = size 2 30 = size 3 |
C3 |
TYPE OF BODY C3 = valve with aluminium body threaded connections |
4 |
NUMBER OF WAYS - FUNCTIONS 1 = 2/2-way - NC 4 = 3/2-way - NC |
04 |
PNEUMATIC CONNECTIONS 04 = G1/8 (size 1) 05 = G1/4 (size 2) 06 = G3/8 (size 3) |
F1 |
ORIFICE DIAMETER F1 = 5.0 mm (size 1) G7 = 6.6 mm (size 2) K1 = 9.0 mm (size 3) |
3 |
SEAL MATERIAL 3 = FKM |
1 |
BODY MATERIAL 1 = aluminium |
Y |
MANUAL OVERRIDE N = not provided Y = provided monostable |
N |
MOUNTING ACCESSORIES N = not provided |
00 |
OPTIONS 00 = no option PP = pneumatic piloting PE = electropilot with external piloting |
2C |
ELECTRICAL CONNECTION 2C = KN 90° type + protection + led - only for size 1 2F = KN in line type + protection + led - only for size 1 3A = DIN EN 175 301-803-C (8 mm) - only for size 2 and 3 4A = industrial standard (9.4 mm) - only for size 2 and 3 7A = 300 mm flying leads - only for size 2 and 3 |
C014 |
VOLTAGE - POWER CONSUMPTION C012 = 12V DC - 1.3/0.25W (size 1) C014 = 24V DC - 1.3/0.25W (size 1) C020 = 12V DC - 2W (size 2 - 3) C023 = 24V DC - 2W (size 2 - 3) C025 = 48V DC - 2W (size 2 - 3) |
VERSION = standard OX1 = for use with oxygen (non volatile residual less than 550 mg/m²) OX2 = for use with oxygen (non volatile residual less than 33 mg/m²) |