Multi-serial Module
CX4 系列
Interface with: PROFIBUS, CANopen, EtherNet/IP, PROFINET, EtherCAT.
Can be integrated with I/O Modules.
Can be integrated with I/O Modules.
Series CX4 multi-serial module can interface with the most common fieldbus protocols, like Profibus-DP, CANOpen, EtherCAT, EtherNet/IP, PROFINET. The possibility to enlarge with both Digital and Analog I/O modules, the acquisition of signals coming from Bridge, RTD or TC sensors, the resolution of up to 24 bit and the high number of manageable signals make it particularly suitable for different needs.
Connectable with PC through MicroUSB port, check and configuration of connected components by means of UVIX software. Configuration through Fieldbus. By means of a mechanical interface connection it is used in combination with the Series D valve islands.
Connectable with PC through MicroUSB port, check and configuration of connected components by means of UVIX software. Configuration through Fieldbus. By means of a mechanical interface connection it is used in combination with the Series D valve islands.
Series
Accessories
there are no salable codes online
If you have entered Filters, try changing them or look in the "Configurator" tab
there are no salable codes online
Look in the "Accessory" tab for the Configurator
addtocart.popup.message.success
请求的数量已部分确认
产品 {0} 已在您的购物车中,数量为 {1} 。您可以从购物车页面更新数量
产品未激活
由于库存不足,无法将此产品添加到购物车
数量必须大于零
产品 {0} 允许的最小数量为 {1}
产品 {0} 允许的最大数量为 {1}
产品 {0} 的包装尺寸是 {1}
无法将代码 {0} 的产品添加到此购物车
出现错误,请稍后重试或联系客户支持
Number of digital outputs | 128 |
Number of analogic outputs | 16 |
Number of digital inputs | 128 |
Number of analogic inputs | 16 |
Maximum input absorption | 1,5 A |
Maximum output absorption | 2,5 A |
Supply voltage | 24 V DC +/-10% logic supply 24 V DC +/-10% power supply |
Protection | overload and reverse polarity |
Protection class | IP65 (IP20 in case of module I/O with terminal block) |
Conform with standards | EN-61131-2 |
Operating temperature | 0-50°C |
Material | polymer |
CX 系列独立总线接口模块代号
CX | 4 | 01 | W | - | 2A2Q | - | R |
CX | SERIES |
4 |
VERSION 4 = CX4 |
01 |
PROTOCOL 00 = Base closed without Fieldbus cover 01 = PROFIBUS 03 = CANopen 04 = EtherNet/IP 05 = EtherCAT 06 = PROFINET |
W |
INTERFACE 0 = No interface W = WLAN |
2A2Q |
INPUT/OUTPUT MODULES 0 = no module A = 8 digital inputs M8 B = 16 digital inputs terminal block (Push-in) connection C = 2 analog inputs (config. 0-10V, ±10V, 0-20mA, 4-20mA, ±20mA) M12 D = 2 analog inputs (config. 0-10V, ±10V, 0-20mA, 4-20mA, ±20mA) terminal block (Push-in) connection E = 2 BRIDGE inputs M12 F = 2 BRIDGE inputs terminal block (Push-in) connection G = 2 RTD inputs M12 (PT100, PT200, PT500, PT1000) H = 2 RTD inputs terminal block (Push-in) connection (PT100, PT200, PT500, PT1000) L = 2 TCM12 inputs (THERMOCOUPLES) M = 2 TC inputs terminal block (Push-in) connection (THERMOCOUPLES) Q = 8 digital outputs M8 R = 16 digital outputs terminal block (Push-in) connection T = 2 Analog outputs (config. 0-10V,±10V,0-20mA, 4-20mA,±20mA), M12 U = 2 Analog outputs (config. 0-10V,±10V,0-20mA,4-20mA,±20mA), terminal block W ** = Closed base without I / O cover |
R |
FIXING TYPE = direct R = DIN rail |
** = The closed base without I / O cover must always be placed after the other modules if present ex: CX401W-2A2W-R...