text.skipToContent text.skipToNavigation
Series F

Series F

Multipole integrated electrical connection (PNP)
Valve functions: 2x2/2; 2x3/2; 5/2; 5/3 CC
It can interface with all major serial communication protocols.
The Multipole version of Series F valve island can be easily integrated with the accessories of the new Series CX multi-serial module, thus connecting to the different serial nets provided.
It is also possible to manage a standard multipole island by means of a Sub-D adapter or through an integrated node in the island. The typical Series F single modularity allows the installation of up to 24 solenoids on 24 valve positions, even in the Fieldbus version.

The use of technopolymer in this Series has allowed to realize a valve island which is characterized by small dimensions, high flow and reduced weight. The reduced dimensions, its flexibility during the assembly as well as the wide range of valve functions make Series F a highly innovative product which is suitable for several application requirements.

Manuals, instruction sheets and configuration files can be found on catalogue.camozzi.com or on the QR code on the lable of the product.
Series
Accessories
there are no salable codes online
If you have entered Filters, try changing them or look in the "Configurator" tab
PNEUMATIC SECTION
Valve construction Spool with seals
Valve functions 5/2 monostable and bistable
5/3 CC
2x2/2 NO
2x2/2 NC
1x2/2 NC + 1x2/2 NO
2x3/2 NO
2x3/2 NC
1x3/2 NC + 1x3/2 NO
Materials aluminium spool - HNBR seals - other seals in NBR - brass cartridges - technopolymer body and end covers
Connections Inlets 2 and 4, size 1 (12 mm) = tube ø4; ø6
Inlets 2 and 4, size 2 (14 mm) = tube ø4; ø6; ø8
Supply 1, size 1 and 2 = tube ø8; ø10
Servo pilot 12/14, size 1 and 2 = tube ø6
Exhausts 3/5, size 1 and 2 = tube ø8; ø10
Exhausts 82/84, size 1 and 2 = tube ø6
Temperature 0 ÷ 50°C
Air specifications Filtered compressed air, non lubricated, class 6.4.4 according to ISO 8573-1:2010 standard.
If lubrication is necessary, please use only oils with maximum viscosity of 32 Cst
and the version with external servo-pilot supply.
The servo-pilot supply air quality class must be 6.4.4 according to ISO 8573-1:2010 standard.
Valve sizes 12 mm
14 mm
Working pressure - 0,9 ÷ 10 bar
Pilot pressure 3 ÷ 7 bar
4.5 ÷ 7 bar
(with working pressure exceeding 6 bar for the versions 2x2/2 and 2x3/2)
Flow rate 250 NI/min (12 mm)
500 NI/min (14 mm)
Mounting position Any position
Duty cycle ED 100%
Protection class (according to EN 60529) IP40
ELECTRICAL SECTION - MULTIPOLE VERSION
Supply voltage

Max number of solenoids

Max number of valve functions

Type of Sub-D connection

Max absorption
24 V DC +/- 10%

24

24 (monostable)

Sub-D 25 pin

0.8 A
ELECTRICAL SECTION - FIELDBUS VERSION
General characteristics

Max absorption


Supply voltage


Max number of operable coils
See the section about the Series CX multi-serial module

digital outputs/analogic outputs and inputs 3 A
digital/analogic inputs 3 A

logic supply 24 V DC +/- 10%
power supply 24 V DC +/- 10%

24 on 24 valve functions (monostable)
Full screen
Coding example - Multipole version
F P 2 R M T A - MB2CMUL2B - 2QR3SLQR
F SERIES
P TYPE
P = pneumatic
A = accessories
2 SIZE
1 = 12 mm
2 = 14 mm
R MANUAL OVERRIDE
P = pressure actuation control
R = actuation control with push & turn device
M ELECTRICAL CONNECTION
M = multipole
T CARTRIDGES FOR LEFT TERMINAL
S = tube Ø 8
T = tube Ø 10

Note: the cartdriges for the right terminal are for tube Ø 6
A SERVO-PILOT SUPPLY
A = internal
B = external
MB2CMUL2B SOLENOID VALVES AND ADDITIONAL PLATES *
M = 5/2 monostable
D = 5/2 monostable with bistable electric board
B = 5/2 bistable
C = 2x3/2 NC
A = 2x3/2 NO
G = 3/2 NC + 3/2 NO
E = 2x2/2 NC
F = 2x2/2 NO
I = 2/2 NC + 2/2 NO
V = 5/3 CC
L = free position with passing electric board
W = free position with bistable electric board
Z = free position with monostable electric board
X = supplementary supply and exhaust
T = separated supply and exhaust
U = separated supply, supplementary exhaust
K = supplementary supply, separated exhaust
2QR3SLQR CARTRIDGES FOR SOLENOID VALVES AND ADDITIONAL PLATES *
Q = tube Ø 4
R = tube Ø 6
S = tube Ø 8 (not for Size 1)
L = free position (no cartridges)
W = free position with bistable electric board (no cartridges)
Z = free position with monostable electric board (no cartridges)
* in case of identical and consecutive codes, in the choices “SOLENOID VALVES AND ADDITIONAL PLATES” and “CARTRIDGES FOR SOLENOID VALVES AND ADDITIONAL PLATES”, replace the letters with the number. 
With the choice “CARTRIDGES FOR SOLENOID VALVES AND ADDITIONAL PLATES” both of the following connections are defined: 2 and 4; 1 and 3/5. 


Examples: FP2RMTA-MBCCMULMMMBB-QQRSSLRRRQRR
                  FP2RMTA-MB2CMUL3M2B-2QR2SL3RQ2R

 
Coding example - Fieldbus version
F P 2 R 00 T A 0 MB2CMUL2B 2QR3SLQR
F SERIES
P TYPE
P = pneumatic
A = accessories
2 SIZE
1 = 12 mm
2 = 14 mm
R MANUAL OVERRIDE
P = pressure actuation control
R = actuation control with push & turn device
00 PROTOCOL
00 = Interface with CX3
01 = PROFIBUS-DP
02 = DeviceNet
03 = CANopen
04 = EtherNet/IP
05 = EtherCAT
06 = PROFINET
99 = Expansion Module
T CARTRIDGES FOR PNEUMATIC/ELECTRICAL TERMINAL
S = tube Ø 8
T = tube Ø 10

Note: the cartdriges for the right terminal are for tube Ø 6
A SERVO-PILOT SUPPLY
A = internal
B = external
0 INPUT/OUTPUT MODULES
0 = no module (mandatory with 00)
A = 8 digital inputs M8
B = 4 digital inputs M8
C = 2 analog inputs 4-20 mA
D = 2 analog inputs 0-10 V
E = 1 analog input 4-20 mA + 1 input 0-10 V
Q = 4 M12 duo digital outputs
R = 2 analog outputs 4-20 mA
T = 2 analog outputs 0-10 V
U = 1 analog output 4-20 mA + 1 output 0-10 V
V = 1 analog output 4-20 mA + 1 input 0-10 V
Z = 1 analog output 4-20 mA + 1 input 4-20 mA
K = 1 analog output 0-10 V + 1 input 0-10 V
Y = 1 analog output 0-10 V + 1 input 4-20 mA
S = Initial subnet module
MB2CMUL2B SOLENOID VALVES AND ADDITIONAL PLATES
M = 5/2 monostable
D = 5/2 monostable with bistable electric board
B = 5/2 bistable
C = 2x3/2 NC
A = 2x3/2 NO
G = 3/2 NC + 3/2 NO
E = 2x2/2 NC
F = 2x2/2 NO
I = 2/2 NC + 2/2 NO
V = 5/3 CC
L = free position with passing electric board
W = free position with bistable electric board
Z = free position with monostable electric board
X = supplementary supply and exhaust
T = separated supply and exhaust
U = separated supply, supplementary exhaust
K = supplementary supply, separated exhaust
2QR3SLQR CARTRIDGES FOR SOLENOID VALVES AND ADDITIONAL PLATES
Q = tube Ø 4
R = tube Ø 6
S = tube Ø 8 (not for Size 1)
L = free position (no cartridges)
W = free position with bistable electric board (no cartridges)
Z = free position with monostable electric board (no cartridges)
CODING EXAMPLES of SINGLE VALVE (spare part) and TERMINALS (accessories)
FP2V-MQR F P 2 V - M Q R FA2T-S F A 2 T - S

CODING EXAMPLE OF A SINGLE SOLENOID VALVE

CODING EXAMPLE OF INTERMEDIATE PLATES
FP2V-MQR FP2V-WQ
F Series F Series
P Type:
P = pneumatic
P Type:
P = pneumatic
2 Size:
1 = 12 mm
2 = 14 mm
2 Size:
1 = 12 mm
2 = 14 mm
V Solenoid valve or additional plate V Solenoid valve or additional plate
M Type of function:
M = 5/2 monostable
D = 5/2 monostable with bistable board
B = 5/2 bistable
C = 2 x 3/2 NC
A = 2 x 3/2 NO
G = 3/2 NC + 3/2 NO
E = 2 x 2/2 NC
F = 2 x 2/2 NO
I = 2/2 NC + 2/2 NO
V = 5/3 CC
W Type of function:
L = free position
W = free position with bistable board
Z = free position with monostable board
X = supplementary power supply and exhaust
T = separated power supply and exhaust
U = separated power supply and supplementary exhaust
K = supplementary power supply and separated exhaust
Q Cartridges for solenoid valves:
Q = Ø4
R = Ø6
S = Ø8 (not for Size 1)
Q Cartridges for plates:
Q = Ø4
R = Ø6
S = Ø8 (not for Size 1)
L = free position (no cartridges)
W = free position with bistable board (no cartridges)
Z = free position with monostable board (no cartridges)
R Type of manual override:
R = push and turn (bistable)
P = pressure (monostable)






CODING EXAMPLE OF A LEFT TERMINAL

CODING EXAMPLE OF A RIGHT TERMINAL
FA2T-S FA2T-AR
F Series F Series
A Accessory A Accessory
2 Size:
1 = 12 mm
2 = 14 mm
2 Size:
1 = 12 mm
2 = 14 mm
T Type of accessory:
T = terminal
T Type of accessory:
T = terminal
S Cartridges:
= no cartridge
S = Ø8
T = Ø10
A Type of servo-pilot:
A = internal
B = external
R Cartridges:
R = Ø6

INDIVIDUAL FIELDBUS version - DIMENSIONS


EXPANSION of the FIELDBUS version - DIMENSIONS