SERIES CST, CSV, CSH CODING EXAMPLE
CS T 2 2 0 N 5 EX
CS SERIES
T TYPE OF SLOT:
T = T-slot
V = V-slot
H = H-slot
2 OPERATION:
2 = Reed NO
3 = Magnetoresistive
4 = Reed NC
5 = Hall effect
2 CONNECTIONS:
2 = 2 wires (Reed only)
3 = 3 wires
5 = 2 wires with M8 connector (Reed only)
6 = 3 wires with M8 connector
0 POWER SUPPLY VOLTAGE:
0 = 10 ÷ 110 V DC; 10 ÷ 230 V AC (PNP)
1 = 30 ÷ 110 V DC; 30 ÷ 230 V AC (PNP)
2 = 3 wires cst (PNP)
3 = 10 ÷ 30 V AC/DC (PNP)
4 = 10 ÷ 27 V DC (PNP)
N NOTE (CST/CSV-250N only):
N = according to norm
5 LENGTH OF THE CABLE:
= 2m (CST and CSV only)
2 = 2m (CSH only)
5 = 5m
EX
SERIES CSB, CSC, CSD CODING EXAMPLE
SERIES CSG CODING EXAMPLE

Magnetic proximity switches with 2 or 3 wire cable for T-slot



Mod. Operation Connections Voltage Output Max. current Max Load Protection L = length cable
CST-220 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8 W None 5 m
CST-220-12 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-220EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 5 m
CST-220-12EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-232 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-232-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-232EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing 2 m
CST-232-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing and overvoltage 5 m
CST-332 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-332EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-432 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-432EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-532 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-532EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
Note for 2-wire switches Mod. CST-220, CST-220-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won’t turn on.
 

Magnetic proximity switches with 2- or 3-wire cable for T-slot



Mod. Operation Connections Voltage Output Max. current Max. load Protection L = length cable
CST-220 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8 W None 5 m
CST-220-12 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-220EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 5 m
CST-220-12EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-232 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-232-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-232EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing 2 m
CST-232-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing and overvoltage 5 m
CST-332 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m


Magnetic proximity switches with 2- or 3-wire cable for T-slot



Mod. Operation Connections Voltage Output Max. current Max Load Protection L = length cable
CST-220 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8 W None 5 m
CST-220-12 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-220EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 5 m
CST-220-12EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-232 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-232-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-232EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing 2 m
CST-232-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing and overvoltage 5 m
CST-332 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-332EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-432 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-432EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-532 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-532EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
Note for 2-wire switches Mod. CST-220, CST-220-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won’t turn on.
 

Magnetic proximity switches with 2 or 3 wire cable for T-slot



Mod. Operation Connections Voltage Output Max. current Max Load Protection L = length cable
CST-220 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8 W None 5 m
CST-220-12 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-220EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 5 m
CST-220-12EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-232 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-232-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-232EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing 2 m
CST-232-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing and overvoltage 5 m
CST-332 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-332EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-432 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-432EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-532 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-532EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
Note for 2-wire switches Mod. CST-220, CST-220-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won’t turn on.
 

Magnetic proximity switches with 2 or 3 wire cable for T-slot



Mod. Operation Connections Voltage Output Max. current Max Load Protection L = length cable
CST-220 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8 W None 5 m
CST-220-12 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-220EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 5 m
CST-220-12EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-232 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-232-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-232EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing 2 m
CST-232-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing and overvoltage 5 m
CST-332 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-332EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-432 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-432EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-532 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-532EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
Note for 2-wire switches Mod. CST-220, CST-220-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won’t turn on.
 

Magnetic proximity switches with 2 or 3 wire cable for T-slot



Mod. Operation Connections Voltage Output Max. current Max Load Protection L = length cable
CST-220 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8 W None 5 m
CST-220-12 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-220EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 5 m
CST-220-12EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-232 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-232-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-232EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing 2 m
CST-232-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing and overvoltage 5 m
CST-332 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-332EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-432 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-432EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-532 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-532EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
Note for 2-wire switches Mod. CST-220, CST-220-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won’t turn on.
 

Magnetic proximity switches with 2 or 3 wire cable for T-slot



Mod. Operation Connections Voltage Output Max. current Max Load Protection L = length cable
CST-220 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8 W None 5 m
CST-220-12 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-220EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 5 m
CST-220-12EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-232 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-232-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-232EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing 2 m
CST-232-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing and overvoltage 5 m
CST-332 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-332EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-432 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-432EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-532 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-532EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
Note for 2-wire switches Mod. CST-220, CST-220-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won’t turn on.
 

Magnetic proximity switches with 2 or 3 wire cable for T-slot Mod. CST

Further details can be found in the “Proximity switch” chapter.



Mod. Operation Connections Voltage Output Max. current Max Load Protection L = length cable
CST-220 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8 W None 5 m
CST-220-12 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-220EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 5 m
CST-220-12EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-232 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-232-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-232EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing 2 m
CST-232-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing and overvoltage 5 m
CST-332 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-332EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-432 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-432EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-532 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-532EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
Note for 2-wire switches Mod. CST-220, CST-220-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won’t turn on.

Magnetic proximity switches with 2- or 3-wire cable for T-slot



Mod. Operation Connections Voltage Output Max. current Max Load Protection L = length cable
CST-220 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8 W None 5 m
CST-220-12 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-220EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 5 m
CST-220-12EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-232 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-232-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-232EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing 2 m
CST-232-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing and overvoltage 5 m
CST-332 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-332EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-432 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-432EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-532 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-532EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
Note for 2-wire switches Mod. CST-220, CST-220-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won’t turn on.
 

Magnetic proximity switches with 2 or 3 wire cable for T-slot Mod. CST



Mod. Operation Connections Voltage Output Max. current Max Load Protection L = length cable
CST-220 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8 W None 5 m
CST-220-12 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-220EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 5 m
CST-220-12EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-232 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-232-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-232EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing 2 m
CST-232-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing and overvoltage 5 m
CST-332 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-332EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-432 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-432EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-532 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-532EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
Note for 2-wire switches Mod. CST-220, CST-220-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won’t turn on.
 

Magnetic proximity switches with 2 or 3 wire cable for T-slot

Cable length: 0,3 m



Mod. Operation Connection Voltage Output Max. current Max Load Protection
CST-250N Reed 2 wires M8 male 3 pin 10 ÷ 110 V AC/DC - 250 mA 10 VA / 8 W None
CST-250NEX Reed 2 wires M8 male 3 pin 10 ÷ 110 V AC/DC - 250 mA 10 VA / 8 W None
CST-262 Reed 3 wires M8 male 3 pin 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing
CST-262EX Reed 3 wires M8 male 3 pin 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing
CST-362 Magnetoresistive 3 wires M8 male 3 pin 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage
CST-362EX Magnetoresistive 3 wires M8 male 3 pin 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage
CST-562 Hall effect 3 wires M8 male 3 pin 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage
CST-562EX Hall effect 3 wiresM8 male 3 pin 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage
Note for 2-wire switch Mod. CST-250N:
in case of polarity reversing the sensor will still be operating, but the LED diode won't turn on

Magnetic proximity switches with 2 or 3 wire cable for T-slot



Mod. Operation Connections Voltage Output Max. current Max Load Protection L = length cable
CST-220 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8 W None 5 m
CST-220-12 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-220EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 5 m
CST-220-12EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-232 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-232-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-232EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing 2 m
CST-232-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing and overvoltage 5 m
CST-332 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-332EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-432 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-432EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-532 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-532EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
Note for 2-wire switches Mod. CST-220, CST-220-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won’t turn on.
 

Magnetic proximity switches with 2- or 3-wire cable for T-slot



Mod. Operation Connections Voltage Output Max. current Max Load Protection L = length cable
CST-220 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8 W None 5 m
CST-220-12 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-220EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 5 m
CST-220-12EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-232 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-232-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-232EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing 2 m
CST-232-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing and overvoltage 5 m
CST-332 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-332EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-432 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-432EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-532 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-532EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
Note for 2-wire switches Mod. CST-220, CST-220-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won’t turn on.
 

Magnetic proximity switches with 2 or 3 wire cable for T-slot



Mod. Operation Connections Voltage Output Max. current Max Load Protection L = length cable
CST-220 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8 W None 5 m
CST-220-12 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-220EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 5 m
CST-220-12EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-232 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-232-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-232EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing 2 m
CST-232-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing and overvoltage 5 m
CST-332 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-332EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-432 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-432EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-532 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-532EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
Note for 2-wire switches Mod. CST-220, CST-220-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won’t turn on.
 

Magnetic proximity switches with 2- or 3-wire cable for T-slot



Mod. Operation Connections Voltage Output Max. current Max Load Protection L = length cable
CST-220 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8 W None 5 m
CST-220-12 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-220EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 5 m
CST-220-12EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-232 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-232-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-232EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing 2 m
CST-232-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing and overvoltage 5 m
CST-332 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-332EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-432 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-432EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-532 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-532EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
Note for 2-wire switches Mod. CST-220, CST-220-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won’t turn on.
 

Magnetic proximity switches with 2- or 3-wire cable for T-slot



Mod. Operation Connections Voltage Output Max. current Max Load Protection L = length cable
CST-220 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8 W None 5 m
CST-220-12 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-220EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 5 m
CST-220-12EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-232 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-232-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-232EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing 2 m
CST-232-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing and overvoltage 5 m
CST-332 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-332EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-432 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-432EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-532 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-532EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
Note for 2-wire switches Mod. CST-220, CST-220-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won’t turn on.
 

Magnetic proximity switches with 2- or 3-wire cable for T-slot



Mod. Operation Connections Voltage Output Max. current Max Load Protection L = length cable
CST-220 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8 W None 5 m
CST-220-12 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-220EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 5 m
CST-220-12EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-232 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-232-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-232EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing 2 m
CST-232-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing and overvoltage 5 m
CST-332 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-332EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-432 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-432EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-532 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-532EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
Note for 2-wire switches Mod. CST-220, CST-220-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won’t turn on.
 

Magnetic proximity switches with 2 or 3 wire cable for T-slot



Mod. Operation Connections Voltage Output Max. current Max Load Protection L = length cable
CST-220 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8 W None 5 m
CST-220-12 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-220EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 5 m
CST-220-12EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-232 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-232-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-232EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing 2 m
CST-232-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing and overvoltage 5 m
CST-332 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-332EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-432 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-432EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-532 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-532EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
Note for 2-wire switches Mod. CST-220, CST-220-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won’t turn on.
 

Magnetic proximity switches with 2 or 3 wire cable for T-slot



Mod. Operation Connections Voltage Output Max. current Max Load Protection L = length cable
CST-220 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8 W None 5 m
CST-220-12 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-220EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 5 m
CST-220-12EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-232 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-232-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-232EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing 2 m
CST-232-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing and overvoltage 5 m
CST-332 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-332EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-432 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-432EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-532 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-532EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
Note for 2-wire switches Mod. CST-220, CST-220-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won’t turn on.
 

Magnetic proximity switches with 2 or 3 wire cable for T-slot



Mod. Operation Connections Voltage Output Max. current Max Load Protection L = length cable
CST-220 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8 W None 5 m
CST-220-12 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-220EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 5 m
CST-220-12EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-232 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-232-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-232EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing 2 m
CST-232-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing and overvoltage 5 m
CST-332 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-332EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-432 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-432EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-532 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-532EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
Note for 2-wire switches Mod. CST-220, CST-220-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won’t turn on.
 

Magnetic proximity switches with 2- or 3-wire cable for T-slot



Mod. Operation Connections Voltage Output Max. current Max Load Protection L = length cable
CST-220 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8 W None 5 m
CST-220-12 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-220EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 5 m
CST-220-12EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-232 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-232-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-232EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing 2 m
CST-232-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing and overvoltage 5 m
CST-332 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-332EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-432 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-432EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-532 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-532EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
Note for 2-wire switches Mod. CST-220, CST-220-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won’t turn on.
 

Magnetic proximity switches with 2 or 3 wire cable for T-slot



Mod. Operation Connections Voltage Output Max. current Max Load Protection L = length cable
CST-220 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8 W None 5 m
CST-220-12 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-220EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 5 m
CST-220-12EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-232 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-232-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-232EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing 2 m
CST-232-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing and overvoltage 5 m
CST-332 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-332EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-432 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-432EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-532 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-532EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
Note for 2-wire switches Mod. CST-220, CST-220-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won’t turn on.
 

Magnetic proximity switches with 2 or 3 wire cable for T-slotMagnetic proximity switches with 2 or 3 wire cable for T-slot



Mod. Operation Connections Voltage Output Max. current Max Load Protection L = length cable
CST-220 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8 W None 5 m
CST-220-12 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-220EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 5 m
CST-220-12EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-232 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-232-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-232EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing 2 m
CST-232-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing and overvoltage 5 m
CST-332 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-332EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-432 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-432EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-532 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-532EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
Note for 2-wire switches Mod. CST-220, CST-220-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won’t turn on.
 

Magnetic proximity switches with 2 or 3 wire cable for T-slot



Mod. Operation Connections Voltage Output Max. current Max Load Protection L = length cable
CST-220 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8 W None 5 m
CST-220-12 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-220EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 5 m
CST-220-12EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-232 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-232-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-232EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing 2 m
CST-232-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing and overvoltage 5 m
CST-332 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-332EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-432 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-432EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-532 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-532EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
Note for 2-wire switches Mod. CST-220, CST-220-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won’t turn on.
 

Magnetic proximity switches with 2 or 3 wire cable for T-slot



Mod. Operation Connections Voltage Output Max. current Max Load Protection L = length cable
CST-220 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8 W None 5 m
CST-220-12 Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-220EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 2 m
CST-220-5EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 5 m
CST-220-12EX Reed 2 wires 10 ÷ 110 V AC/DC-230 V AC - 250 mA 10 VA / 8W None 12 m
CST-232 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-232-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-232EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing 2 m
CST-232-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP 250 mA 10 VA / 8W Against polarity reversing and overvoltage 5 m
CST-332 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5 Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-332EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-332-5EX Magnetoresistive 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-432 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5 Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-432EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 2 m
CST-432-5EX Reed 3 wires 5 ÷ 30 V AC/DC PNP-NC 250 mA 10 VA / 8 W Against polarity reversing 5 m
CST-532 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5 Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
CST-532EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 2 m
CST-532-5EX Hall effect 3 wires 10 ÷ 27 V DC PNP 100 mA 6 W Against polarity reversing and overvoltage 5 m
Note for 2-wire switches Mod. CST-220, CST-220-5:
in case of polarity reversing the sensor will still be operating, but the LED diode won’t turn on.
 

We think you are in United States.
Update your location?