text.skipToContent text.skipToNavigation
Series 6PF

Series 6PF

Double-acting low friction, magnetic
ø 50, 63, 80, 100, 125 mm
Series 6PF pneumatic actuators are equipped with a potentiometric linear position transducer integrated inside the rod. This type of cylinder allows, along the entire stroke, a constant control of the rod position which is read processing the change of the transducer internal resistance.
The pistons have been equipped with a permanent magnet which enables the use of external end-stroke sensors.
The dynamic seals are specific for low friction.

Thanks to the electrical connection, realized by means of an M12 male electric round connector positioned on the rear head, these cylinders fulfil the standards of IP67 protection class.
Series 6PF cylinders comply with the ISO 15552 standards and can be assembled with the entire range of standard accessories. They are available with bores from 50mm to 125mm with standard strokes from 50mm to 1000mm with intervals of 50mm.
The sturdy design, the flexible installation and the high performance make Series 6PF suitable for use in applications with tensioning cylinders, positioning cylinders and filling, cutting and measuring systems.
Series
Accessories
  • 1(current)
  • 2
  • 3
166 Products found
Cylinder transducer - 6PF3P050A0050
Series 6PF
Cylinder transducer - 6PF3P050A0085
Series 6PF
Cylinder transducer - 6PF3P050A0100
Series 6PF
Cylinder transducer - 6PF3P050A0100EX
Cylinder transducer - 6PF3P050A0100V
Series 6PF
Cylinder transducer - 6PF3P050A0100VEX
Cylinder transducer - 6PF3P050A0150
Series 6PF
Cylinder transducer - 6PF3P050A0150EX
Cylinder transducer - 6PF3P050A0150G
Series 6PF
Cylinder transducer - 6PF3P050A0150V
Series 6PF
- 6PF3P050A0185
Cylinder transducer - 6PF3P050A0200
Series 6PF
  • 1(current)
  • 2
  • 3
PNEUMATIC SECTION
Construction inner tie-rods
Operation double-acting low friction, not cushioned
Materials see the table on the following page
Mountings front and rear flange
foot mounts
front / rear / swivel / intermediate trunnion
Bores 50, 63, 80, 100, 125 mm
Strokes min - max 50 ÷ 1000 mm (step 50 mm)
Operating temperature 0°C ÷ 80°C (with dry air -20°C)
Operating pressure 0,1 ÷ 10 bar
Speed (min - max) 5 ÷ 1000 mm/sec (no load)
Max acceleration 10 m/sec²
Fluid filtered air class 5.4.4 according to ISO 8573-1.
If lubricated air is used, it is recommended to use oil ISOVG32. Once applied the lubrication should never be interrupted.
Linearity 0,1% of the stroke
Repeatability 0,03% of the stroke
Resolution Infinite
Hysteresis < di 0,5 mm
Vibration test according EN 60068-2-6 severity level 3
Shock test according EN 60068-2-27 severity level 2
ELECTRICAL SECTION
Electrical connection male connector M12 4 poles
IP 67 (EN 60529)
Max input voltage 40 V (stroke 50 mm)
60 V (strokes from 100 to 500 mm)
Max recommended cursor current < di 0,1 µA
Electrical resistance 5 kohm for strokes from 50 to 300 mm
10 kohm for strokes from 350 to 500 m
Tolerance on resistance +/- 20%
Max dissipation (40°C) 1 W for stroke 50 mm
2 W for stroke 100 mm
3 W for strokes from 150 to 500 mm
Suitable end-stroke sensors CST-532 (3 wires)
CST-562 (M8)
Suitable M12 connectors CS-LF04HB (connecteur droit femelle 4 pôles)
CS-LR04HB (connecteur femelle à angle droit 4 pôles)
CS-LF05HB-D200 (connecteur filaire femelle droit, 5 pôles, 2 mètres) **
CS-LF05HB-D500 (connecteur filaire femelle droit, 5 pôles, 5 mètres) **
CS-LR05HB-D200 (connecteur coudé à angle droit, femelle, 5 pôles, 2 mètres) **
CS-LR05HB-D500 (connecteur filaire femelle à angle droit 5 pôles, 5 mètres) **

** la broche n ° 5 ne doit pas être connectée
Full screen
Your configuration
CODING EXAMPLE
6PF 3 P 050 A 0200
6PF SERIES
3 OPERATION:
3 = double-acting low friction, no cushion
PNEUMATIC SYMBOLS
CD22
P MATERIALS:
P = see the table on the following page
050 BORES:
050 = 50 mm
063 = 63 mm
080 = 80 mm
100 = 100 mm
125 = 125 mm
A CONSTRUCTION:
A = standard with rod nut
RL = cylinder with rod lock
0200 STROKES (see the table)
VERSIONS:
= standard
P = PU rod seal
V = FKM rod seal
L = without rod seal (rear supply only) *
G = with brass rod scraper
EX = ATEX
( _ _ _ ) = extended piston rod _ _ _ mm


* The possibility to order the cylinder without piston rod seal
further reduces the friction force.