text.skipToContent text.skipToNavigation
Serie CX4

Serie CX4

Interface with: PROFIBUS, CANopen, EtherNet/IP, PROFINET, EtherCAT.
Can be integrated with I/O Modules.
Series CX4 multi-serial module can interface with the most common fieldbus protocols, like Profibus-DP, CANOpen, EtherCAT, EtherNet/IP, PROFINET. The possibility to enlarge with both Digital and Analog I/O modules, the acquisition of signals coming from Bridge, RTD or TC sensors, the resolution of up to 24 bit and the high number of manageable signals make it particularly suitable for different needs.

Connectable with PC through MicroUSB port, check and configuration of connected components by means of UVIX software. Configuration through Fieldbus. By means of a mechanical interface connection it is used in combination with the Series D valve islands.
Series
Accessories
there are no salable codes online
If you have entered Filters, try changing them or look in the "Configurator" tab
Número de salidas digitales 128
Número de salidas analógicas 16
Número de entradas digitales 128
Número de entradas analógicas 16
Máxima absorción de entrada 1,5 A
Máxima absorción de salida 2,5 A
Tensión de alimentación 24 V DC +/-10% alimentación lógica
24 V DC +/-10% alimentación eléctrica
Protección sobrecarga y polaridad inversa
Clase de protección IP65 (IP20 en caso de módulo I/O con bloque de terminales)
Según la norma EN-61131-2
Temperatura de funcionamiento 0-50°C
Material polímero
Pantalla completa
Tu configuración
EJEMPLO DE CODIFICACIÓN
CX 4 01 W - 2A2Q - R
CX SERIES
4 VERSION
4 = CX4
01 PROTOCOL
00 = Base closed without Fieldbus cover
01 = PROFIBUS
03 = CANopen
04 = EtherNet/IP
05 = EtherCAT
06 = PROFINET
W INTERFACE
0 = No interface
W = WLAN
2A2Q INPUT/OUTPUT MODULES
0 = no module
A = 8 digital inputs M8
B = 16 digital inputs terminal block (Push-in) connection
C = 2 analog inputs (config. 0-10V, ±10V, 0-20mA, 4-20mA, ±20mA) M12
D = 2 analog inputs (config. 0-10V, ±10V, 0-20mA, 4-20mA, ±20mA) terminal block (Push-in) connection
E = 2 BRIDGE inputs M12
F = 2 BRIDGE inputs terminal block (Push-in) connection
G = 2 RTD inputs M12 (PT100, PT200, PT500, PT1000)
H = 2 RTD inputs terminal block (Push-in) connection (PT100, PT200, PT500, PT1000)
L = 2 TCM12 inputs (THERMOCOUPLES)
M = 2 TC inputs terminal block (Push-in) connection (THERMOCOUPLES)
Q = 8 digital outputs M8
R = 16 digital outputs terminal block (Push-in) connection
T = 2 Analog outputs (config. 0-10V,±10V,0-20mA, 4-20mA,±20mA), M12
U = 2 Analog outputs (config. 0-10V,±10V,0-20mA,4-20mA,±20mA), terminal block
W ** = Closed base without I / O cover
R FIXING TYPE
= direct
R = DIN rail
** = The closed base without I / O cover must always be placed after the other modules if present ex: CX401W-2A2W-R...