text.skipToContent text.skipToNavigation
Series W

Series W

Supplied with:
1x interface for NO with position ports as per NC
(ports 1 and 3 are inverted)
2x interface seals
2x M3x25 screws for mounting on metal
Series
Accessories
there are no salable codes online
If you have entered Filters, try changing them or look in the "Configurator" tab
Full screen
Your configuration
CODING EXAMPLE
W 0 00 3 0 3 W 2 3
W SERIES
0 BODY DESIGN
0 = single sub-base (only M5) or interface
1 = single manifold
2 = double manifold
00 NUMBER OF POSITIONS
00 = ISO 15218 interface
01 = single base (M5 only)
02 ÷ 99 = manifold number of positions
3 NUMBER OF WAYS - FUNCTIONS
0 = manifold or single sub-base
3 = 3/2-way - NC
4 = 3/2-way - NO
5 = 3/2-way - NC electric part revolved by 180°
6 = 3/2-way - NO electric part revolved by 180°
0 VALVE PORTS
0 = ISO 15218 interface

MANIFOLD PORTS for P - PL - PN - W Series
2 = M5 thread - front outlets
3 = tube Ø 3 mm fittings - front outlets
4 = tube Ø 4 mm fittings - front outlets
6 = M5 thread - bottom outlets
7 = tube Ø 3 mm fittings - bottom outlets
8 = tube Ø 4 mm fittings - bottom outlets
3 ORIFICE DIAMETER
1 = Ø 0.8 mm
3 = Ø 1.5 mm
5 = Ø 1.1 mm - NC versions
6 = Ø 1.5 mm - NC versions with voltage tolerance -25% ÷ +10%
5 = Ø 0.9 mm - NO versions
W MATERIALS
E = PBT body - EPDM seals
F = PBT body - FKM seals
W = PBT body - NBR - FKM - PU seals
2 ELECTRICAL CONNECTION
1 = 300 mm flying leads
2 = DIN EN 175 301-803-C (8 mm)
3 VOLTAGE - POWER CONSUMPTION
2 = 12 V DC - 2 W
3 = 24 V DC - 1 W - NC Ø 0.8 mm version only
3 = 24 V DC - 2 W
4 = 48 V DC - 2 W
FIXING
= fixing screws for metal
P = fixing screws for plastic
OPTIONS:
= standard
OX1 = for use with oxygen (non volatile residual less than 550 mg/m²)
OX2 = for use with oxygen (non volatile residual less than 33 mg/m²)

Series W solenoid valve - 3/2-way NO - DIN EN 175 301-803-C (8 mm)



Mod. Function Orifice Ø (mm) kv (l/min) Min÷max pressure (bar) Power (W)
W000-405-*2* 3/2 NO 0,9 0,23 0÷10 2
W000-403-*2* 3/2 NO 1,5 0,39 0÷5 2
W000-605-*2* 3/2 NO 0,9 0,23 0÷10 2
W000-603-*2* 3/2 NO 1,5 0,39 0÷5 2
* add
- MATERIALS
- VOLTAGE (see CODING EXAMPLE)